Gent S4-711-VAD-HPR Dual Optical Heat Sensor, Red VAD

- Load factor per device
- 10
- Maximum devices per loop
- 100
- Approx Weight
- 0.11Kg (0.17Kg with base) Kg
- Operating Temperature
- -10°C to +50°C
- VAD coverage (High Intensity)
- C-3-14 (Also Open Category C-4.5-14)
- VAD coverage (Medium Intensity)
- C-3-13 (Also Open Category C-4-13)
- EN54 certification
- Smoke Part 7, Heat Part 5, VAD Part 23, Sounder & Voice Sounder Part 3, Isolator Part 17, Input/Output Part 18
Required to operate
Needed to install, power or certify this product.

IP21 base and base cover (pack of 1)
VAD requires the IP21 base/mounting plate to achieve IP21 and EN54-23 compliance.

Base - Common for all S-Quad Sensors
S-Quad sensor plugs into its dedicated S4-700 base

IP21 base covers (pack 5)
VAD/Sounder S-Quad must use Base with IP21 Plate to meet Standards
Overview
What it is and how it fits the system.
The Gent S4-711-VAD-HPR is an S4 dual optical and heat sensor with an integral high-performance red Visual Alarm Device. It combines smoke and heat detection with high-performance red visual signalling in one addressable unit. With a load factor of 10, up to 100 are supported per loop.
Technical overview
S4-711-VAD-HPR is a Gent by Honeywell S4 Dual OH (Dual Optical & Heat) sensor with an integral High Performance Red VAD, part of the S4 Detectors range and its Detectors with VAD sub-range. It combines smoke and heat detection with high-performance red visual signalling in one addressable unit, carrying a load factor of 10 and supporting up to 100 devices per loop.
The unit operates from -10°C to +50°C and offers selectable red VAD coverage across high, medium and low intensity settings (C-3-14, C-3-13 and C-3-10 respectively, each with an open-category alternative). It holds EN54 certification covering smoke and heat detection (Parts 7 and 5), the visual alarm device (Part 23), sounder and voice sounder output (Part 3), the loop isolator (Part 17) and input/output functions (Part 18), spanning EN54-5, 7, 17, 18 and 23.
It runs on the addressable loop circuit alongside sensors, sounders, manual call points and interface units, up to a combined maximum of 127 devices, with the loop protecting no more than 10,000 m² of a site. Where installed in a Nano panel based system, (HP) S-Quad devices revert to LOW VAD performance only. Compliant mounting requires the IP21 base and base cover (S4-701), the common S4-700 base and IP21 base covers (S4-705), while the 34000 S-Quad Adapter Base (S4-700-34K) is recommended for retrofitting onto an existing 34000 base. It supersedes the S4-711-ST. For physical connections, refer to the installation manual.
Specifications
Full technical data for this part.
| Description | S4 Dual OH/Red VAD (HP) |
|---|---|
| Load factor per device | 10 |
| Maximum devices per loop | 100 |
| Approx Weight | 0.11Kg (0.17Kg with base) Kg |
| Operating Temperature | -10°C to +50°C |
| VAD coverage (High Intensity) | C-3-14 (Also Open Category C-4.5-14) |
| VAD coverage (Medium Intensity) | C-3-13 (Also Open Category C-4-13) |
| VAD coverage (Low Intensity) | C-3-10 |
| EN54 certification | Smoke Part 7, Heat Part 5, VAD Part 23, Sounder & Voice Sounder Part 3, Isolator Part 17, Input/Output Part 18 |
| Dimensions (diameter / height, mm) | 49.6 (63.8 with base) / 117 (140 with base and IP 21 plate) mm |
| EN54 parts | EN54-5, 7, 17, 18 & 23 |
Specifications sourced from manufacturer documentation.
Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know
Enhancements (optional)
Optional additions — this product works without them.

34000 S-Quad Adapter Base
Compatible 34000 S-Quad adapter base for retrofitting this sensor onto an existing 34000 base.