Gent Remote LED for ES Detect
| Part no. | 781814 |
|---|---|
| Brand | Gent |
| Range | Conventional Audio Visual Devices |
| Sub-range | Remote LED Indicator |

Image for illustration; item supplied may differ
Description
The 781814 is a remote LED indicator for the ES Detect conventional fire detector range, repeating detector status at an accessible location away from the device itself. Housed in a white (RAL 9010) ABS-V0 enclosure measuring 115mm in diameter and 24mm deep, it weighs approximately 60g and accepts conductors from 1.5mm2 to 2.5mm2. Built for continuous service, it operates across an ambient range of -20C to +54C at relative humidity below 95% non-condensing.
The 781814 is a Conventional Remote LED indicator for the ES Detect conventional fire detector range. Housed in a white (RAL 9010) ABS-V0 enclosure measuring 115mm in diameter and 24mm deep, it weighs approximately 60g and accepts conductors from 1.5mm2 to 2.5mm2. Built for continuous service, it operates across an ambient range of -20°C to +54°C at relative humidity below 95% non-condensing.
Read the full technical description
The 781814 is a Conventional Remote LED indicator for the ES Detect conventional fire detector range. Housed in a white (RAL 9010) ABS-V0 enclosure measuring 115mm in diameter and 24mm deep, it weighs approximately 60g and accepts conductors from 1.5mm2 to 2.5mm2. Built for continuous service, it operates across an ambient range of -20°C to +54°C at relative humidity below 95% non-condensing.
The device repeats detector status at an accessible location away from the fire detector itself. It is compatible with the Base (805590-D) and can be wired to zone terminals of conventional fire panels, as well as Mains or LV interface units in Vigilon or SENTRI systems. Physical wiring details are specified in the installation manual. Additionally, it supports connection to Xenex Control Panels including models 13270-02LB, 13270-04LB, and 13270-08LB for approved system integration.
Specifications
| Description | Remote LED for ES Detect |
|---|---|
| Dimensions | Depth 24 mm x 115 mm diameter |
| Weight | 60g approximately |
| Colour | White (RAL 9010) |
| Housing | ABS-V0 |
| Ambient temperature | -20°C to +54°C |
| Storage temperature | -25°C to +70°C |
| Ambient humidity | < 95% relative humidity (non condensing) |
| Terminals | 1.5mm2 to 2.5mm2 |
Specifications per manufacturer documentation, subject to change. E&OE.
Documents
| Document | Type | Size | Download |
|---|---|---|---|
| Installation manual (781814, 805590-D) | Installation | 863 KB | Download PDF |
Optional accessories
- 805590-DDetector Base With DiodeUsed with the Base (805590-D) for the ES Detect range of conventional fire detectors£6.16ex VAT£7.39 inc VATIn stock
- 805590Detector Base. Can be used for ES Conventional and Intrinsically safe detection.Used with the Base (805590-D) for the ES Detect range of conventional fire detectors£5.98ex VAT£7.18 inc VATIn stock
- 13270-08LBGent 8 Zone conventional panel, EN54 less batteriesES Detect range is only approved to be installed with Xenex Control Panels - 13270-02LB, 1£339.66ex VAT£407.59 inc VATIn stock
- 13270-02LB2 Zone conventional panel, EN54 less batteriesES Detect range is only approved to be installed with Xenex Control Panels - 13270-02LB, 1£196.14ex VAT£235.37 inc VATIn stock
- 13270-04LBGent 4 Zone conventional panel, EN54 less batteriesES Detect range is only approved to be installed with Xenex Control Panels - 13270-02LB, 1£263.72ex VAT£316.46 inc VATIn stock
- S4-34440-02Mains Powered Interface - max o/p power 1.5A. Batteries not included - requires 2 x 4015-502-YFR (Power Sonic Flame Retardant 12V 2.1Ah) to meet compliance regulations.Can be wired to a Mains interface unit installed in a Vigilon or SENTRI fire panel based s£461.66ex VAT£553.99 inc VATIn stock
- S4-34440-12Mains Powered Interface - max o/p power 2.5A. Batteries not included - requires 2 x 4015-514-YFR (Power Sonic Flame Retardant 12V 12Ah) to meet compliance regulations.Can be wired to a Mains interface unit installed in a Vigilon or SENTRI fire panel based s£577.67ex VAT£693.20 inc VATIn stock
- S4-344504 Channel Interface (input/output) (no enclosure)Can be wired to an LV interface unit installed in a Vigilon or SENTRI fire panel based sys£163.85ex VAT£196.62 inc VATIn stock
+ 5 moreShow fewer
- S4-34410Single Channel Interface, LV Input only (no enclosure)Can be wired to an LV interface unit installed in a Vigilon or SENTRI fire panel based sys£58.01ex VAT£69.61 inc VATIn stock
- 800171Fixed Heat DetectorCompatible fire detectors (ES Detect range): 800171 Fixed Heat detector, 800177 Fixed Heat£20.46ex VAT£24.55 inc VATIn stock
- 800177Fixed Heat Detector Class BCompatible fire detectors (ES Detect range): 800171 Fixed Heat detector, 800177 Fixed Heat£31.70ex VAT£38.04 inc VATIn stock
- 800271Rate of Rise Heat DetectorCompatible fire detectors (ES Detect range): 800171 Fixed Heat detector, 800177 Fixed Heat£21.05ex VAT£25.26 inc VATIn stock
- 800371Optical Smoke DetectorCompatible fire detectors (ES Detect range): 800171 Fixed Heat detector, 800177 Fixed Heat£20.99ex VAT£25.19 inc VATIn stock