Conventional Xenex Panels
Xenex 13270-02LB 2 Zone Conventional Fire Panel
- Maximum load per zone
- 3mA
- Max sounder circuit load
- 500mA per circuit max 1A combined
- Battery standby
- 72 hours (1mA per zone + 0.5A sounder load max)
- Standby duration
- 72hr standby
- Standby supply
- A period of 72 hours followed by 30 minutes of alarm load is possible and is dependent on the system loading.
- 24v power supply max current
- 250mA (1 & 2 zone)
- Operating temperature and humidity
- 0 - 40 oC low to +95% RH non condensing
Overview
What it is and how it fits the system.
The 13270-02LB is a 2-zone conventional fire alarm control panel from the Xenex range, EN54-rated and supplied less batteries. Each zone carries up to 3mA load, with sounder circuits rated 500mA each to a combined maximum of 1A. It supports 72-hour standby followed by 30 minutes of alarm load using 2 x 12V sealed lead-acid batteries (2.1Ah to 3.4Ah), fed via a 5A fused spur unit.
Technical overview
The 13270-02LB is a two-zone conventional fire alarm control panel from the Xenex range, certified to EN54 and shipped without batteries. It drives detection and sounder circuits across two zones on conventional radial wiring using standard two-core cable, and is designed for indoor installation.
Backup power comes from a pair of 12V sealed lead-acid batteries, which the panel is engineered to sustain for a 72-hour standby period followed by around 30 minutes at full alarm load, depending on how the system is loaded. Mains connection is made through a fused spur.
Certification covers both EN54-2 for control and indicating equipment and EN54-4 for the power supply, carrying BSI approval KM 553763 under certificate 0086-CPD-553764. The design follows the 1997 editions of those standards together with their later amendments.
The panel works with a broad set of conventional field devices, including optical smoke, fixed-temperature and rate-of-rise heat detectors, manual call points, sounders and strobes. A repeat indicator and remote LED can be added where secondary annunciation is needed, and replacement mouldings and cover plates support ongoing servicing.
Specifications
Full technical data for this part.
| Order code | 13270-02LB |
|---|---|
| Description | 2 ZONE CONVENTIONAL PANEL, EN54 LESS BATTERIES |
| Maximum load per zone | 3mA |
| Max sounder circuit load | 500mA per circuit max 1A combined |
| Battery standby | 72 hours (1mA per zone + 0.5A sounder load max) |
| Standby duration | 72hr standby |
| Standby supply | A period of 72 hours followed by 30 minutes of alarm load is possible and is dependent on the system loading. |
| Batteries | 2 x 12V, 2.1 Ah min |
| Battery supply | Battery supply (sealed lead acid) 2-off 12V 2.1Ah - 3.4Ah |
| Mains supply | via a fused spur unit rated 5A - 1 & 2 Zone panel/Repeat panel |
| 24v power supply max current | 250mA (1 & 2 zone) |
| Weight approx with batteries | 5.8Kg |
| Operating environment | Indoor, 0 - 40ºC |
| Operating temperature and humidity | 0 - 40 oC low to +95% RH non condensing |
Specifications sourced from manufacturer documentation.
Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know
Optional accessories
Optional additions — this product works without them.
Flush Plate for 1-8 Panel and Repeat Panel Variants
compatible / works with: Flush Plate for 1-8 Panel and Repeat Panel Variants

8 Zone repeat indicator, less batteries
compatible / works with: 8 Zone repeat indicator, less batteries
Remote LED for ES Detect
compatible / works with: Remote LED for ES Detect
Fixed Heat Detector Class B
compatible / works with: Fixed Heat Detector Class B
Rate of Rise Heat Detector
compatible / works with: Rate of Rise Heat Detector
Optical Smoke Detector
compatible / works with: Optical Smoke Detector
Spares & replacement parts
Replacement parts for units already in service.
Replacement Mouldings and Cover Plates
Replacement mouldings and cover plates for Xenex panels
Compare variants
Alternatives in the same range — pick the variant that fits your install.

Gent 4 Zone conventional panel, EN54 less batteries

Gent 8 Zone conventional panel, EN54 less batteries
Guides
In-depth selection and installation guidance.