Gent 8 Zone conventional panel, EN54 less batteries

Part no.13270-08LB
BrandGent
RangeConventional Xenex Panels
Sub-rangeFire Panel
Conventional 8 Zone conventional panel, EN54 less batteries — main product photo

Image for illustration; item supplied may differ

Description

The 13270-08LB is an 8-zone conventional fire control panel from the Xenex/3270 range, EN54-approved and supplied without batteries. Operating from a 230V ac +10% -15% 50Hz mains supply, it delivers 72-hour standby followed by 30 minutes of alarm load using 2 x 12V 3.4Ah sealed lead-acid batteries. Replacement cells are listed in the manufacturer's datasheet under OEM spare-part code 4014-509-Y (a datasheet reference code, not a direct order line) for straightforward maintenance of larger eight-zone conventional systems.

The 13270-08LB is an eight-zone conventional fire alarm control panel in the Xenex 3270 range, approved to EN54 Parts 2 and 4 and also listed under order code 75585-08NMB. It is catalogued under Conventional Xenex Panels as a fire panel. Front-panel controls use a numeric keypad to sound the alarm, silence it, reset the system and cancel the buzzer, and a software-selectable false-alarm verification feature filters spurious activations.

Read the full technical description

The 13270-08LB is an eight-zone conventional fire alarm control panel in the Xenex 3270 range, approved to EN54 Parts 2 and 4 and also listed under order code 75585-08NMB. It is catalogued under Conventional Xenex Panels as a fire panel. Front-panel controls use a numeric keypad to sound the alarm, silence it, reset the system and cancel the buzzer, and a software-selectable false-alarm verification feature filters spurious activations.

Power is drawn from a 230V ac 50Hz mains feed with a +10% to -15% tolerance. Each of the eight zones accepts a maximum load of 3 mA across up to twenty diode bases, spur wiring off a zone is not permitted, and every circuit is monitored by a 22 µF end-of-line capacitor after the last device, with a 470 ohm series resistor in each manual call point. Sounder circuits deliver up to 500 mA apiece within a 1 A combined ceiling, a 24V auxiliary output is rated to 500 mA, and 72 hours of standby followed by 30 minutes at alarm load is achievable, subject to system loading.

Field wiring follows conventional radial layouts in standard two-core cable, carrying optical, beam and duct smoke detectors, fixed-temperature and rate-of-rise heat detectors, alongside sounders, strobes and bells. The eight-zone XENS-MCB-8 board sits at the panel's core, the 13270-29 kit allows recessed flush mounting, and a single eight-zone repeat indicator can be driven over the serial port, one per system. Two auxiliary relay contacts and a zone disablement facility complete the control provisions.

Specifications

Order code alternate75585-08NMB
Description8 ZONE CONVENTIONAL PANEL, EN54 LESS BATTERIES
Supplied without batteriesThe panels are supplied without batteries
Batteries2 x 12V, 3.4 Ah
Battery supply2-off 12V 2.1Ah - 3.4Ah (sealed lead acid)
Spare battery part4014-509-Y (BATTERIES FOR 8 ZONE XENEX USE 2 X 3.4AH 12V)
Battery standby72 hours (1mA per zone + 0.5A sounder load max)
Standby duration72hr standby
Standby supply72 hours followed by 30 minutes of alarm load is possible and is dependent on the system loading
Mains operating voltage230V ac +10% -15% 50Hz
Mains supply fused spur7A - 4 & 8 Zone panel
Maximum load per zone3mA
Max sounder circuit load500mA per circuit max 1A combined
24v aux supply max current500mA (4 & 8 zone)

Specifications per manufacturer documentation, subject to change. E&OE.