Conventional Xenex Panels
Xenex 13270-08LB 8 Zone Conventional Fire Panel

- Order code alternate
- 75585-08NMB
- Supplied without batteries
- The panels are supplied without batteries
- Batteries
- 2 x 12V, 3.4 Ah
- Battery supply
- 2-off 12V 2.1Ah - 3.4Ah (sealed lead acid)
- Spare battery part
- 4014-509-Y (BATTERIES FOR 8 ZONE XENEX USE 2 X 3.4AH 12V)
- Mains operating voltage
- 230V ac +10% -15% 50Hz
- 24v aux supply max current
- 500mA (4 & 8 zone)
You will also need
Needed to install, power or certify this product.
Detector Base With Diode
Diode base for detector heads on the panel's zone circuits (continuity when a head is removed), max 20 per zone.
Overview
What it is and how it fits the system.
The 13270-08LB is an 8-zone conventional fire control panel from the Xenex/3270 range, EN54-approved and supplied without batteries. Operating from a 230V ac +10% -15% 50Hz mains supply, it delivers 72-hour standby followed by 30 minutes of alarm load using 2 x 12V 3.4Ah sealed lead-acid batteries. Replacement cells are listed in the manufacturer's datasheet under OEM spare-part code 4014-509-Y (a datasheet reference code, not a direct order line) for straightforward maintenance of larger eight-zone conventional systems.
Technical overview
The 13270-08LB is an eight-zone conventional fire alarm control panel in the Xenex 3270 range, approved to EN54 Parts 2 and 4 and also listed under order code 75585-08NMB. It is catalogued under Conventional Xenex Panels as a fire panel. Front-panel controls use a numeric keypad to sound the alarm, silence it, reset the system and cancel the buzzer, and a software-selectable false-alarm verification feature filters spurious activations.
Power is drawn from a 230V ac 50Hz mains feed with a +10% to -15% tolerance. Each of the eight zones accepts a maximum load of 3 mA across up to twenty diode bases, spur wiring off a zone is not permitted, and every circuit is monitored by a 22 µF end-of-line capacitor after the last device, with a 470 ohm series resistor in each manual call point. Sounder circuits deliver up to 500 mA apiece within a 1 A combined ceiling, a 24V auxiliary output is rated to 500 mA, and 72 hours of standby followed by 30 minutes at alarm load is achievable, subject to system loading.
Field wiring follows conventional radial layouts in standard two-core cable, carrying optical, beam and duct smoke detectors, fixed-temperature and rate-of-rise heat detectors, alongside sounders, strobes and bells. The eight-zone XENS-MCB-8 board sits at the panel's core, the 13270-29 kit allows recessed flush mounting, and a single eight-zone repeat indicator can be driven over the serial port, one per system. Two auxiliary relay contacts and a zone disablement facility complete the control provisions.
Specifications
Full technical data for this part.
| Order code alternate | 75585-08NMB |
|---|---|
| Description | 8 ZONE CONVENTIONAL PANEL, EN54 LESS BATTERIES |
| Supplied without batteries | The panels are supplied without batteries |
| Batteries | 2 x 12V, 3.4 Ah |
| Battery supply | 2-off 12V 2.1Ah - 3.4Ah (sealed lead acid) |
| Spare battery part | 4014-509-Y (BATTERIES FOR 8 ZONE XENEX USE 2 X 3.4AH 12V) |
| Battery standby | 72 hours (1mA per zone + 0.5A sounder load max) |
| Standby duration | 72hr standby |
| Standby supply | 72 hours followed by 30 minutes of alarm load is possible and is dependent on the system loading |
| Mains operating voltage | 230V ac +10% -15% 50Hz |
| Mains supply fused spur | 7A - 4 & 8 Zone panel |
| Maximum load per zone | 3mA |
| Max sounder circuit load | 500mA per circuit max 1A combined |
| 24v aux supply max current | 500mA (4 & 8 zone) |
Specifications sourced from manufacturer documentation.
Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know
Optional accessories
Optional additions — this product works without them.
Flush Plate for 1-8 Panel and Repeat Panel Variants
compatible / works with: Flush Plate for 1-8 Panel and Repeat Panel Variants

8 Zone repeat indicator, less batteries
compatible / works with: 8 Zone repeat indicator, less batteries
Remote LED for ES Detect
compatible / works with: Remote LED for ES Detect
Fixed Heat Detector Class B
compatible / works with: Fixed Heat Detector Class B
Rate of Rise Heat Detector
compatible / works with: Rate of Rise Heat Detector
Optical Smoke Detector
compatible / works with: Optical Smoke Detector
Spares & replacement parts
Replacement parts for units already in service.
Replacement Mouldings and Cover Plates
Replacement mouldings and cover plates for Xenex panels
Compare variants
Alternatives in the same range — pick the variant that fits your install.
2 Zone conventional panel, EN54 less batteries

Gent 4 Zone conventional panel, EN54 less batteries
Guides
In-depth selection and installation guidance.