Vigilon Plus
Gent Vigilon VIGPLUS-24 4-Loop Fire Panel EN54

- Panel type
- Vigilon Plus 4 Loop Panel
- Max no of loops
- 4
- Battery standby
- 24hrs +30 mins in alarm (4 loop, integrated)
- Integral psu
- Integral EN54-4 PSU and battery standby for 24 hours (4 loop)
- Batteries
- 2 x 21Ah
- Max quantity per loop
- Up to 200 Devices per Loop
- Approvals
- EN54 Parts 2 & 4
Required to operate
Needed to install, power or certify this product.

1 to 4 Loop Vigilon Plus Control Panel without printer c/w 1 loop card & supplied in black. Recommend the use of fixed CLSS Gateway HON-CGW-MBB as a digital printer. Batteries not included - requires 2 x 4015-602-YFR (Power Sonic Flame Retardant 12V 21Ah) to meet compliance regulations.
VIGPLUS-24-NP — 1 TO 4 LOOP CONTROL PANEL - NO PRINTER (sibling order code)

Vigilon Plus Repeat Panel supplied in black. Batteries not included - requires 2 x 4015-501-YFR (Power Sonic Flame Retardant 12V 7Ah) to meet compliance regulations.
VIGILON PLUS REPEAT PANEL VIGPLUS-RPT
Overview
What it is and how it fits the system.
The VIGPLUS-24 is a Vigilon Plus analogue addressable fire detection control panel supporting 1 to 4 loops, from the Vigilon Plus range of advanced fire detection control panels. It carries an integral EN54-4 PSU with 24 hours plus 30 minutes alarm standby on 2 x 21Ah batteries, and supports up to 200 devices per loop. The panel weighs 22 kg including batteries and operates from 0 to 45ºC.
Technical overview
VIGPLUS-24 is the one-to-four loop Vigilon Plus control panel from Gent by Honeywell, an analogue addressable fire detection panel approved to EN54 Parts 2 & 4. Each loop accepts up to 200 devices over loop lengths of up to 2.5 km (2.5km with 2.5mm cable CSA or 2km with 1.5mm cable CSA), and all Vigilon devices connect onto the same two core loop, so separate sounder or repeater panel wiring circuits are not required. EN54-2 restricts Vigilon 4 and 6 loop panels to a maximum of 512 sensors and call points.
The panel carries an integral EN54-4 PSU giving 24 hours standby plus 30 minutes in alarm when fitted with 2 x 21Ah batteries, and operates from 0-45ºC. An 8-line x 40 character back-lit LCD display with push-button keypad handles control, and networking of up to 200 panels in a multi-domain structure runs over copper or optic fibre using the VIG-NC or VIG-NC-FO network cards.
VIGPLUS-24 supersedes the VIG1-24. Loop expansion uses the VIG-LPC-EN loop card, while the VIG-24-FLUSH flush surround, VIG-DOOR-SS stainless steel door, VIG-FLUSH-SS stainless steel flush mounting kit and custom colour doors cover installation finishes; the VIGPLUS-RPT repeat panel and the VIG72-UPGR 72-hour standby upgrade kit extend the system further.
Specifications
Full technical data for this part.
| Order code | VIGPLUS-24 |
|---|---|
| Panel type | Vigilon Plus 4 Loop Panel |
| Description | 1 TO 4 LOOP CONTROL PANEL |
| Max no of loops | 4 |
| Battery standby | 24hrs +30 mins in alarm (4 loop, integrated) |
| Integral psu | Integral EN54-4 PSU and battery standby for 24 hours (4 loop) |
| Batteries | 2 x 21Ah |
| Approx weight | 22 Kg (inc batteries) |
| Operating temp | 0-45ºC |
| Loop capacity | 200 with Alarm Current 800mA (Max Alarm current across both loops (1.2 A) |
| Max quantity per loop | Up to 200 Devices per Loop |
| Loop length | Loop Length up to 2.5 km |
| Cable length | 2.5km with 2.5mm cable CSA / 2km with 1.5mm cable CSA |
| Approvals | EN54 Parts 2 & 4 |
Specifications sourced from manufacturer documentation.
Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know
Enhancements (optional)
Optional additions — this product works without them.

Network Card for VIGPLUS-24 and VIGPLUS-72 Vigilon Panels (EN54)
VIGILON NETWORK CARD (COPPER) VIG-NC

Fibre Optic Network Card for VIG1-24 and VIG1-72 Vigilon Panels (EN54 & V3+)
VIGILON NETWORK CARD (MULTIMODE FIBRE) VIG-NC-FO

Loop Card for VIGPLUS-24 and VIGPLUS-72 Vigilon Panels (EN54)
VIGILON LOOP CARD VIG-LPC-EN
Loop Card for VIG1-24 and VIG1-72 Vigilon Panels (EN54). Supports 3400, 34000 & Pre-VAD Squad devices.
VIGILON LOOP CARD VIG-LPC-EN

Flush Surround (Main Control Panel and Terminal Node)
FLUSH SURROUND VIG-24-FLUSH
Stainless Steel Door for Vigilon Main Control Panel
STAINLESS STEEL DOOR FOR VIGILON MAIN CONTROL PANEL VIG-DOOR-SS

Vigilon Main Control Panel Flush Mounting Kit (Stainless Steel)
STAINLESS STEEL FLUSH MOUNTING KIT FOR VIGILON MAIN CONTROL PANEL VIG-FLUSH-SS

Upgrade Kit to convert Vigilon 24 to Vigilon 72. Batteries not included - requires 4 x 4015-602-YFR (Power Sonic Flame Retardant 12V 21Ah) to meet compliance regulations. Also requires additional Battery Enclosure VS-BATTBOX-72.
Upgrade kit to extend the 1-to-4 loop (24hr) panel standby to 72 hours.