Loop Card · Gent Legacy

Gent Vigilon VIG-LPC EN Loop Card for 4/6 Loop Panels

Product type
Loop Card
Panel compatibility
is for use in Vigilon 4/6 loop panels only
Max loop length
Up to 1km loop
Loop device support
Up to 1km loop length is possible with a mix of S4, S3 Mark 1/2 and 3400 devices installed on a loop circuit
Replacement use
The Older Loop cards (VIG-LPC or COMPACT-LPC) can only be used as replacement cards for the same build, as a like for like replacement card
Replacement restriction
MUST NEVER BE USED as replacement for Post March 2014 Loop Cards (VIG-LPC-EN or COMPACT-LPC-EN) where longer loop length of up to 2km exist or where compliant Part 23 devices are installed on Loop circuits
Standard
Vigilon Fire System GENT 2012 Designed to EN54 Pt 2 & 4

Overview

What it is and how it fits the system.

The VIG-LPC is an older-build EN Vigilon loop card for use in Vigilon 4/6 loop panels only, supporting loop lengths of up to 1km with a mix of S4, S3 Mark 1/2 and 34K devices. Designed to EN54 Parts 2 & 4, the older loop cards may only be used as replacements and must never be used in place of post-March 2014 loop cards. The Loop Diagnostic Tool cannot be used to diagnose Vigilon panels fitted with this card.

Technical overview

The VIG-LPC is an older-build EN Vigilon loop card by Gent by Honeywell, designed for use exclusively in Vigilon 4/6 loop panels. It supports loop lengths of up to 1km when used with a combination of S4, S3 Mark 1/2 and 3400 devices on the circuit. The card is designed to EN54 Parts 2 & 4 standards as specified in the Vigilon Fire System GENT 2012 documentation.

This card is strictly intended as a like-for-like replacement for older-build loop cards and must never be used to replace post-March 2014 loop cards such as the VIG-LPC-EN or COMPACT-LPC-EN, particularly where loop lengths extend to 2km or where EN54 Part 23 compliant devices are installed. Additionally, the Loop Diagnostic Tool cannot be used to diagnose Vigilon panels that have this card fitted, limiting diagnostic capabilities to alternative methods.

Specifications

Full technical data for this part.

Product typeLoop Card
Panel compatibilityis for use in Vigilon 4/6 loop panels only
Max loop lengthUp to 1km loop
Loop device supportUp to 1km loop length is possible with a mix of S4, S3 Mark 1/2 and 3400 devices installed on a loop circuit
Replacement useThe Older Loop cards (VIG-LPC or COMPACT-LPC) can only be used as replacement cards for the same build, as a like for like replacement card
Replacement restrictionMUST NEVER BE USED as replacement for Post March 2014 Loop Cards (VIG-LPC-EN or COMPACT-LPC-EN) where longer loop length of up to 2km exist or where compliant Part 23 devices are installed on Loop circuits
Diagnostic tool limitationThe Loop Diagnostic Tool CANNOT be used to diagnose Vigilon panel fitted with Loop Cards (VIG-LPC or COMPACT-LPC)
StandardVigilon Fire System GENT 2012 Designed to EN54 Pt 2 & 4

Specifications sourced from manufacturer documentation.

Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know