S4 MCPs & Accessories
Gent S4-34896 Weatherproof Manual Call Point, EN54

- Standards
- EN54 part 11 & 17
- En54 compliance
- These devices will comply fully with EN54 Part11
- Element options
- Option of glass or resettable element
- Mounting options
- Surface or Semi Flush options
- Semi flush flange colour
- Semi-flush flanges shall be available in black
- Integral isolator
- 2 integral Line Isolators
- Electronics sealing
- All electronic devices contained within the MCP shall be sealed so as to prevent damage from hostile environment conditions: i.e. dust, up to a rating of IP32
Overview
What it is and how it fits the system.
The Gent S4-34896 is a manual call point supplied with a weatherproof enclosure, complying fully with EN54 Part 11 (and Part 17). Each MCP contains its own microprocessor for a response time of less than one second, with two integral line isolators and a flashing integral LED to denote operation of the break glass. Available with a glass or resettable element in surface or semi-flush mounting, the device can be functionally tested in place, and its sealed electronics suit demanding environments.
Technical overview
Gent by Honeywell S4-34896 is a manual call point with a weatherproof enclosure, part of the wider Gent Manual Call Point range. It carries two integral line isolators, and a flashing LED signals that the break glass has been triggered, cancelling only once the point is reset.
The call point can be specified with a glass or resettable element and mounted on the surface or semi-flush, with black flanges for the semi-flush version. A functional test can be run in place without removing the cover or breaking the glass, using the supplied test key that slots into a keyway hidden beneath a sliding cover. The internal electronics are sealed against dust and other hostile conditions to an IP32 rating, and the device conforms to EN54 Part 11 and Part 17.
Specifications
Full technical data for this part.
| Standards | EN54 part 11 & 17 |
|---|---|
| En54 compliance | These devices will comply fully with EN54 Part11 |
| Element options | Option of glass or resettable element |
| Mounting options | Surface or Semi Flush options |
| Semi flush flange colour | Semi-flush flanges shall be available in black |
| Integral isolator | 2 integral Line Isolators |
| Response time | Each MCP shall contain its own microprocessor ensuring a less than 1 second response time from initiation |
| Indicator | Upon operation of the break glass the integral LED will flash to denote operation, this being cancelled upon the operation of a reset procedure |
| Functional test | The device can be tested functionally without the need to either remove the front cover and/or break the glass, using a special test key (supplied as standard). The key shall insert in a keyway concealed by a sliding cover. |
| Electronics sealing | All electronic devices contained within the MCP shall be sealed so as to prevent damage from hostile environment conditions: i.e. dust, up to a rating of IP32 |
Specifications sourced from manufacturer documentation.
Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know