ex-VAT pricing shown

Now open for trade ordersGent, Morley-IAS & Xtralis stock added weekly — open to the trade.

S4 MCPs & Accessories

Gent S4-34896 Weatherproof Manual Call Point, EN54

S4-34896 — Hero
Standards
EN54 part 11 & 17
En54 compliance
These devices will comply fully with EN54 Part11
Element options
Option of glass or resettable element
Mounting options
Surface or Semi Flush options
Semi flush flange colour
Semi-flush flanges shall be available in black
Integral isolator
2 integral Line Isolators
Electronics sealing
All electronic devices contained within the MCP shall be sealed so as to prevent damage from hostile environment conditions: i.e. dust, up to a rating of IP32

Overview

What it is and how it fits the system.

The Gent S4-34896 is a manual call point supplied with a weatherproof enclosure, complying fully with EN54 Part 11 (and Part 17). Each MCP contains its own microprocessor for a response time of less than one second, with two integral line isolators and a flashing integral LED to denote operation of the break glass. Available with a glass or resettable element in surface or semi-flush mounting, the device can be functionally tested in place, and its sealed electronics suit demanding environments.

Technical overview

Gent by Honeywell S4-34896 is a manual call point with a weatherproof enclosure, part of the wider Gent Manual Call Point range. It carries two integral line isolators, and a flashing LED signals that the break glass has been triggered, cancelling only once the point is reset.

The call point can be specified with a glass or resettable element and mounted on the surface or semi-flush, with black flanges for the semi-flush version. A functional test can be run in place without removing the cover or breaking the glass, using the supplied test key that slots into a keyway hidden beneath a sliding cover. The internal electronics are sealed against dust and other hostile conditions to an IP32 rating, and the device conforms to EN54 Part 11 and Part 17.

Specifications

Full technical data for this part.

StandardsEN54 part 11 & 17
En54 complianceThese devices will comply fully with EN54 Part11
Element optionsOption of glass or resettable element
Mounting optionsSurface or Semi Flush options
Semi flush flange colourSemi-flush flanges shall be available in black
Integral isolator2 integral Line Isolators
Response timeEach MCP shall contain its own microprocessor ensuring a less than 1 second response time from initiation
IndicatorUpon operation of the break glass the integral LED will flash to denote operation, this being cancelled upon the operation of a reset procedure
Functional testThe device can be tested functionally without the need to either remove the front cover and/or break the glass, using a special test key (supplied as standard). The key shall insert in a keyway concealed by a sliding cover.
Electronics sealingAll electronic devices contained within the MCP shall be sealed so as to prevent damage from hostile environment conditions: i.e. dust, up to a rating of IP32

Specifications sourced from manufacturer documentation.

Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know