  • Intrinsically Safe Multisensor Detector803374.EX is an O2H-multisensor detector working Intrinsically Safe Areas Detection inside the Gent by Honeywell IS range.
  • Ex Protection And CertificateThe detector is Ex ib IIC T4, in ATEX category II 2G alongside safety barrier Part No. 764744, certificate TÜV 09 ATEX 554910.
  • Multi Standard SpecificationStandard specification is EN 54-7: 2006 / -5 B: 2000 / A1: 2002, CEA 4021.
  • VdS And CE ApprovalsVdS approval is G 204061 and the CE certificate is 0786 - CPD - 20105/20106.
  • Area And Mounting HeightThe multisensor watches max. 110 m² from heights to max. 12 m.
  • Quiescent CurrentQuiescent draw is 60 μ A @ 19 V DC, the supply spanning 8 V DC to 42 V DC.
  • Multisensor Ambient RangeAmbient temperature is -20 °C to +65 °C and storage covers -25 °C to +75 °C.
  • Eight Detectors Per ZoneQuantity of detectors is limited to a maximum of 8 per zone.

Description

Part No. 805590 is the detector base 803374.EX seats in, and the multisensor is one of the Ex sensors tested for operation with the Vigilon system. Detector quantity is limited to 8 per zone.

The sensing type for the part is Smoke, watching over max. 110 m² from as high as max. 12 m, with alarm signalled by a red LED, flashing. Consumption of 60 μ A @ 19 V DC sits inside an 8 V DC to 42 V DC working range, while intrinsic safety is bounded by 21 V DC, 252 mA, 10 mA and 1 nF.

803374.EX is an O2H-multisensor detector serving Intrinsically Safe Areas Detection within the Gent by Honeywell IS range. The Ex protection code is Ex ib IIC T4, and ATEX category II 2G applies with the safety barrier, Part No. 764744, while the examination certificate number is TÜV 09 ATEX 554910.

Its standard specification is EN 54-7: 2006 / -5 B: 2000 / A1: 2002, CEA 4021, with VdS approval G 204061 and CE certificate 0786 - CPD - 20105/20106. Type of sensor is Smoke, covering max. 110 m² over a mounting height reaching max. 12 m. Quantity of detectors is limited to a maximum of 8 per zone.

Quiescent consumption reads 60 μ A @ 19 V DC, with 8 V DC to 42 V DC as the working supply. Entity limits read 21 V DC input voltage, 252 mA input current, 10 mA output current and 1 nF internal capacity. Ambient temperature for the multisensor is -20 °C to +65 °C, where the ATEX range figure is - 20 °C to + 70 °C.

Read the full technical description

The galvanic isolator, part number 17740-30, must be positioned as near as it can be to the Ex zone being monitored (Zone 1), preferably inside a Vigilon Mains powered Interface housing, either S4-34440-02 or S4-34440-12. Its specification covers EN 54-7: 2006 / -5 B: 2000 / A1: 2002 and CEA 4021, with VdS approval G 204061 and CE certificate 0786 - CPD - 20105/20106.

803374.EX is an O2H-multisensor detector serving Intrinsically Safe Areas Detection within the Gent by Honeywell IS range. The Ex protection code is Ex ib IIC T4, and ATEX category II 2G applies with the safety barrier, Part No. 764744, while the examination certificate number is TÜV 09 ATEX 554910.

Its standard specification is EN 54-7: 2006 / -5 B: 2000 / A1: 2002, CEA 4021, with VdS approval G 204061 and CE certificate 0786 - CPD - 20105/20106. Type of sensor is Smoke, covering max. 110 m² over a mounting height reaching max. 12 m. Quantity of detectors is limited to a maximum of 8 per zone.

Quiescent consumption reads 60 μ A @ 19 V DC, with 8 V DC to 42 V DC as the working supply. Entity limits read 21 V DC input voltage, 252 mA input current, 10 mA output current and 1 nF internal capacity. Ambient temperature for the multisensor is -20 °C to +65 °C, where the ATEX range figure is - 20 °C to + 70 °C.

Storage temperature runs from -25 °C to +75 °C, with humidity at ≤ 95% relative, non-condensing, and air velocity across 0 to 5.000 ft/min. The white ABS body, similar to RAL 9010, has a mass of approx. 110 g and an outline with base of Ø 117 mm, H = 62 mm, with IP 43 following from a base plus the optional base gasket.

Specifications

Operating voltage8 V DC to 42 V DC
Ambient temperature-20 °C to +65 °C
Alarm indicatorred LED, flashing
IP ratingIP 43 (with base + optional base gasket)
HousingABS
ColourWhite (similar to RAL 9010)
Weightapprox. 110 g
Dimensions (with base)Ø 117 mm, H = 62 mm
Ambient humidity≤ 95% relative, (non-condensing)
Storage temperature-25 °C to +75 °C
EN54 standardEN 54-7 : 2006 / -5 B : 2000 / A1 : 2002, CEA 4021
VdS approvalG 204061
CE certificate0786 - CPD - 20105/20106
Ex-protectionEx ib IIC T4 Gb