Gent 1.5m Venturi Tube
| Part no. | S4-34760-15 |
|---|---|
| Brand | Gent |
| Range | S4 Duct & Accessories |
| Sub-range | Venturi Tubes |

Image for illustration; item supplied may differ
At a glance
- 1.5 m tube length1500 mm Venturi tube for the Gent S4-34760 duct housing.
- 600 to 1400 mm duct diameterSized for this duct diameter band, with the tube trimmed during installation.
- 0.6 kg tube weightThe S4-34760-15 tube weighs 0.6 kg.
- Support at the opposite wallThe fitted tube passes through the far side of the duct for support.
- Cut to the installation lengthAllow for about 30 mm projection beyond the far wall, never more than 30 mm, and any mounting bracket spacing.
- Gasket and screw connectionFits the housing’s oval opening with a rubber gasket and the housing kit’s short retaining screw.
Description
The Gent S4-34760-15 is a 1.5 m Venturi tube for the S4-34760 duct housing. It suits duct diameters from 600 to 1400 mm and weighs 0.6 kg. The tube takes air from the duct to the detector housed outside it. Cut the tube to suit the duct, with support at the far wall and an end cap in place. The entry hole is 38 mm and the far wall hole is 50 mm. Allow for the spacing of a mounting bracket when setting the length. The S4-34760-99 bracket is required on round or insulated ducts. A short screw secures the tube at the housing. The housing connection uses a rubber gasket at its oval opening.
The S4-34760-15 is the 1500 mm Venturi tube for the S4-34760 duct housing. Its duct diameter band is 600 to 1400 mm, and its weight is 0.6 kg. Air passes through the tube to the detector inside the externally mounted housing.
Read the full technical description
The S4-34760-15 is the 1500 mm Venturi tube for the S4-34760 duct housing. Its duct diameter band is 600 to 1400 mm, and its weight is 0.6 kg. Air passes through the tube to the detector inside the externally mounted housing.
Trim the tube to the installed duct size. It passes through the opposite duct wall, where it needs support, and projects about 30 mm beyond that wall, without exceeding 30 mm. The cut length must also allow for the spacing between the housing and duct when a mounting bracket is fitted.
The housing-side duct opening is 38 mm in diameter; the opposite-wall opening is 50 mm. Deburr the 38 mm opening and fit the seals at the duct penetration. At the housing, fit the rubber gasket around the tube, insert it into the oval opening and secure it with the housing kit's short screw. Close the free end with the end cap.
Use the S4-34760-99 mounting bracket for circular or insulated ducts. The bracket bends to the duct shape and has pre-punched fixing holes. The housing arrow must follow the air flow, with the tube positioned centrally across the duct.
Specifications
| Product type | Venturi sampling tube |
|---|---|
| Compatible housing | S4-34760 |
| Tube length | 1500 mm / 1.5 m |
| Suitable duct diameter | 600 to 1400 mm |
| Tube weight | 0.6 kg |
| Length adjustment | Cut to suit duct and mounting arrangement |
| Far-wall support | Required at opposite duct wall |
| Housing-side duct bore | 38 mm diameter |
|---|---|
| Opposite-wall duct bore | 50 mm diameter |
| Tube end projection | About 30 mm beyond opposite wall; maximum 30 mm. Allow for bracket spacing when cutting |
| Housing connection | Rubber gasket, oval entry and short retaining screw |
| End termination | End cap fitted |
| Circular or insulated duct installation | S4-34760-99 bracket required |
Specifications per manufacturer documentation, subject to change. E&OE.
Documents
| Document | Type | Size | Download |
|---|---|---|---|
| Datasheet (S4-34760-15, S4-34760-28, S4-34760-99) | Datasheet | 152 KB | Download PDF |
| Installation manual (S4-34760-15, S4-34760-28, S4-34760-99) | Installation | 1.3 MB | Download PDF |
Optional accessories
- S4-34760Duct Housing (Inc S Quad BASE AND 0.6M TUBE)Used with the S4-34760 Duct Smoke Sensor / Air duct kit (S4-34760_Venturi-Air Duct Kit)£541.08ex VAT£649.30 inc VATIn stock
- S4-34760-99Mounting BracketThe optional mounting kit (Part No. S4-34760-99) is used for mounting on insulated or circ£135.75ex VAT£162.90 inc VATIn stock
- S4-34760-282.8m Venturi TubeAvailable alongside sibling Venturi tubes: 600 mm (S4-34760-06) and 2800 mm (S4-34760-28)£150.08ex VAT£180.10 inc VATIn stock
- S4-715S4 Optical DetectorDuct sensor housing uses an S-Quad Optical Sensor (Part No. S4-715)£38.88ex VAT£46.66 inc VATIn stock
FAQs
Which ducts suit the S4-34760-15 tube?
The S4-34760-15 suits duct diameters from 600 to 1400 mm and has a supplied length of 1500 mm. It works with the S4-34760 housing, which sits outside the duct while the tube extends across the air stream. Trim the tube to suit the installation and support it at the opposite wall. For duct diameters from 1400 to 2700 mm, the corresponding longer option is the 2800 mm S4-34760-28, fitted to the same housing.
How should the S4-34760-15 be cut to length?
Cut the tube to suit the duct diameter and the housing's mounting position. The fitted tube passes through the far duct wall and projects about 30 mm beyond it, without exceeding 30 mm. When a bracket holds the housing away from the duct, allow for that spacing in the overall cut length. Fit the cap to the free end once the tube is trimmed, and support the tube at the opposite wall. The housing end is retained by a short screw.
What duct openings does the S4-34760-15 need?
The long-tube installation uses two duct openings: a 38 mm hole on the housing side and a 50 mm hole in the opposite wall. Deburr the 38 mm opening before fitting. The far-wall opening supports the tube as it crosses the duct, and the penetration needs its seal. The tube end is capped beyond that wall. At the housing, a separate rubber gasket sits around the tube where it enters the oval opening and is secured with the short screw.
How does the S4-34760-15 connect to the housing?
Fit the rubber gasket at the tube's housing end, insert that end into the oval opening in the S4-34760 and secure it with the housing kit's short screw. The tube carries duct air into the chamber containing the separate detector. Position the tube centrally across the duct and align the housing arrow with the airflow. The 1500 mm tube also needs support at the opposite wall, with its free end capped after it has been cut to length.
Does the S4-34760-15 installation need a bracket?
Circular or insulated ducts require the S4-34760-99 bracket for the S4-34760 housing. The bracket bends to follow the duct shape and has pre-punched mounting holes. Its spacing between the housing and duct must be included when setting the tube's cut length. The S4-34760-15 still needs support at the opposite wall and an end cap. Use its 600 to 1400 mm duct diameter band when sizing the installation, with the housing arrow aligned to the airflow.