ex-VAT pricing shown

Now open for trade ordersGent, Morley-IAS & Xtralis stock added weekly — open to the trade.

SINGLE CHANNEL OUTPUT ONLY INTERFACE C/W RELAY AND ENCLOSURE · S4 Interfaces & Accessories

Gent S4-34415 Single Channel Output Interface

S4-34415 — Hero
Type
SINGLE CHANNEL OUTPUT ONLY INTERFACE C/W RELAY AND ENCLOSURE
Power source
Loop powered
Approvals
Approval EN54-17: 2005 and EN54-18: 2005 LPCB
Short circuit handling
Each device with EN54-17 short circuit handling for enhanced system integrity
Addressing
Individual addresses to maximise information and flexible cause and effect
Relative humidity
Up to 95% – Temperature +5ºC to +45°C (Non condensing)
Panel compatibility
Compatible with Loop = V3.93 / V4.35 and Main Control Card = V3.94 / V4.37

Overview

What it is and how it fits the system.

The Gent S4-34415 is a loop-powered single channel output-only interface, supplied complete with relay and enclosure for the Vigilon system. It carries LPCB approval to EN54-17:2005 and EN54-18:2005, with EN54-17 short-circuit handling and individual addressing for enhanced system integrity and flexible cause-and-effect. The unit operates in up to 95% relative humidity (non-condensing) across +5C to +45C and is compatible with Loop software V3.93/V4.35 and Main Control Card V3.94 and above.

Technical overview

The S4-34415 is a loop-powered single channel output-only interface from Gent by Honeywell, part of the Vigilon range within the S4 Interfaces & Accessories sub-range of Low Voltage Interfaces. Built around an integral relay and enclosure, it provides addressable switched-output control within fire detection and alarm systems that call for individual addressing and enhanced integrity. As a mains-switching interface it draws power directly from the detection loop, so no separate local supply is needed.

The unit holds LPCB approval to EN54-17:2005 and EN54-18:2005. Per-device short-circuit handling under EN54-17 helps the loop keep functioning through fault conditions, while individual addressing maximises information flow and supports flexible cause-and-effect programming across the Vigilon architecture. It is rated for non-condensing operation and works with the current Vigilon Loop and Main Control Card software revisions. Physical wiring and terminal connection details are documented in the installation manual.

Specifications

Full technical data for this part.

Order codeS4-34415
TypeSINGLE CHANNEL OUTPUT ONLY INTERFACE C/W RELAY AND ENCLOSURE
Power sourceLoop powered
ApprovalsApproval EN54-17: 2005 and EN54-18: 2005 LPCB
Short circuit handlingEach device with EN54-17 short circuit handling for enhanced system integrity
AddressingIndividual addresses to maximise information and flexible cause and effect
Relative humidityUp to 95% – Temperature +5ºC to +45°C (Non condensing)
Panel compatibilityCompatible with Loop = V3.93 / V4.35 and Main Control Card = V3.94 / V4.37

Specifications sourced from manufacturer documentation.

Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know