Morley-IAS Analogue Addressable Monitor Module for Supervision of a Conventional Zone Equipped with EOL Resistor

Part no.M210EA-CZR
BrandMorley-IAS
RangeAddressable Interface modules
Sub-rangeZone Monitor
ReplacesM210E-CZR
Morley IAS M210EA-CZR conventional zone monitor module, white rectangular device with green terminal block shown from front. — main product photo

Image for illustration; item supplied may differ

£105.85 ex VAT
£127.02 inc VAT
In stock
Ships in 1 to 2 working days
Dates are based on our supplier's lead times and may change.
Free UK delivery over £250 ex VAT, otherwise £9.95 ex VAT (£11.94 inc VAT).

Volume pricing

Bulk discount, applied automatically at checkout.

QuantityUnit price ex VAT
1+£105.85
5+£102.67
10+£101.09
20+£99.50

Don't forget

Description

The M210EA-CZR is the conventional zone interface module in the resistive end-of-line version, supplied with a 3.9 kΩ End of Line Resistor. Conventional Zone External Supply Voltage is 14.5 to 28.5 V and the Maximum Zone Load is 60 mA, limited internally.

The M210EA-CZR is a conventional zone interface module. The M200 series of modules are a family of microprocessor controlled interface devices permitting the monitoring of a conventional zone.

Read the full technical description

It is the resistive end-of-line version: the End of Line Resistor is 3.9 kΩ, 5%, and it is supplied.

Conventional Zone External Supply Voltage is 14.5 to 28.5 V, and the Maximum Zone Load is 60 mA, limited internally. Maximum Conventional Line Resistance is 50 Ω.

Ingress protection is IP44 when mounted in an M200E-SMB, and the box dimensions are 132 mm (H) x 137 mm (W) x 40 mm (D).

Specifications

Led cutoff voltage16.5 V Max.
Standby current - conventional zone, no communication (external supply, @24 v, 25 °c)120 µA Max.
Standby current - conventional zone, no communication (loop powered, @24 v, 25 °c)6.3 mA
Led current (red)1.3 mA
Led current (yellow)4.5 mA
Conventional zone external supply voltage14.5 to 28.5 V (18 to 28.5 V if loop powered)
Maximum standby load current2.8 mA for detectors at 18 V; 3.8 mA for detectors at 24 V
Maximum zone load60 mA (limited internally)
Maximum conventional line resistance50 Ω
End of line resistor3.9 kΩ, 5% (supplied)
Humidity5% to 95% relative humidity (non-condensing)
Ingress protection (mounted in m200e-smb)IP44
Maximum wire gauge2.5 mm²

Specifications per manufacturer documentation, subject to change. E&OE.