Gent S3 Voice Sounder red Body
| Part no. | S3-V-R |
|---|---|
| Brand | Gent |
| Range | S3 Sounders & VADs |
| Sub-range | Wall Voice Sounders |

Image for illustration; item supplied may differ
At a glance
- S-Cubed Mark 3 voice sounderA red bodied wall voice sounder for Gent Vigilon Plus, Compact Plus and Nano addressable systems. This model has no visual alarm device.
- Four spoken messages and a bell toneS-Cubed voice sounders store four spoken messages and a bell tone. The female announcements cover emergency evacuation, awaiting instructions and a test; the male announcement is for fire alarm evacuation. Message 3 with Signal 1 and Message 5 with Signal 2 are approved to EN 54-3 Annex C. The message and attention tone period defaults to 10 seconds and can be set up to 30 seconds; audio and bell-tone storage is up to 20 seconds.
- Loop powered with an integral isolatorThe S3-V-R has an integral short circuit isolator meeting EN 54-17. The indoor S-Cubed range uses a 35V to 48V loop supply and loop in/out connections.
- S-Cubed tone and volume adjustmentFor S-Cubed voice sounders, the S3-CONTROL infrared remote selects tone, speech message and volume from up to 3m away while the panel is in test mode. Hold the remote's power button to store the device settings. After a volume adjustment, save the new level at the panel.
- Indoor S-Cubed housing and base optionsThe indoor S-Cubed range is rated IP 21, with a 112mm square face and wall projection of 90mm on the standard base or 75mm on the optional shallow base. The S3-BASE-SR shallow base is red and comes in packs of five.
- EN 54-3 sounder and EN 54-17 isolatorThis voice sounder meets EN 54-3 and has a short circuit isolator meeting EN 54-17. It provides spoken messages as well as tones and a bell tone.
Description
The Gent S3-V-R is a red bodied wall voice sounder in the S-Cubed Mark 3 range, for Gent Vigilon Plus, Compact Plus and Nano addressable systems. It provides three alarm tones, four spoken messages and a bell tone. Two message and tone combinations are approved to EN 54-3 Annex C. It is loop powered and has an integral short circuit isolator. The indoor S-Cubed range is rated IP 21 for internal walls. Tone and volume can be set with the commissioning tool or S3-CONTROL infrared remote. The matching S3-BASE-SR shallow base is optional. The indoor range has a 112mm square face and projects 90mm on the standard base or 75mm on the optional shallow base. Supplied with a matching red standard base and one screw fitted in the base.
The S3-V-R is the red bodied voice sounder in Gent's S-Cubed Mark 3 range. It is loop powered and compatible with Gent Vigilon Plus, Compact Plus and Nano systems. It provides tones and spoken alarms without a visual alarm device.
Read the full technical description
The S3-V-R is the red bodied voice sounder in Gent's S-Cubed Mark 3 range. It is loop powered and compatible with Gent Vigilon Plus, Compact Plus and Nano systems. It provides tones and spoken alarms without a visual alarm device.
S-Cubed sounders provide three LPCB approved signals: an intermittent 970Hz tone at 1Hz, alternating 730Hz and 970Hz tones at 2Hz, and a continuous 970Hz tone. Each tone frequency has a tolerance of +/-10%. The range sounder rating is 103dB(A) +/-3dB, measured at 90 degrees and 1m. S-Cubed voice sounders store four spoken messages and a bell tone. The female announcements cover emergency evacuation, awaiting instructions and a test; the male announcement is for fire alarm evacuation. Message 3 with Signal 1 and Message 5 with Signal 2 are approved to EN 54-3 Annex C. The message and attention tone period defaults to 10 seconds and can be set up to 30 seconds; audio and bell-tone storage is up to 20 seconds.
The indoor S-Cubed range uses a 35V to 48V loop supply and loop in/out terminals 01, L1, 02 and L2; the loop screen connects to the metal box earth. The S3-V-R has an integral short circuit isolator meeting EN 54-17. The indoor range is rated IP 21 for internal wall positions. Its body is polycarbonate and the base is ABS. The indoor S-Cubed range has a 112mm square face and projects 90mm on the standard base or 75mm on an optional shallow base. The S3-BASE-SR shallow base matches this red body and comes in packs of five. Allow at least 10cm below the ceiling when fitting a shallow base so that the locking screw remains accessible. Keep the TOP mark facing upwards and the cable tails within 10cm. The base must remain surface mounted and the enclosure unpainted.
Vigilon commissioning uses the Vigilon Commissioning Tool V1.30 or later. For S-Cubed voice sounders, the S3-CONTROL infrared remote selects tone, speech message and volume from up to 3m away while the panel is in test mode. Hold the remote's power button to store the device settings. After a volume adjustment, save the new level at the panel. S-Cubed sounders and visual alarm devices synchronise across all loops of one panel; synchronisation does not extend across a network of panels.
Specifications
| Manufacturer's designation | S3 Voice Sounder/Red Body |
|---|---|
| Device type | Wall mounted voice sounder, Gent S-Cubed Mark 3 range, for indoor use on internal walls |
| Visual alarm device | None fitted; audible alarm only |
| Sound output | S-Cubed sounder range rating: 103dB(A) +/-3dB at 90 degrees and 1m. |
| Tones | S-Cubed sounder signals: 1, intermittent 970Hz at 1Hz; 2, alternating 730Hz and 970Hz at 2Hz; 3, continuous 970Hz. Tone frequencies have a +/-10% tolerance. All three signals are LPCB approved. |
| Speech messages | S-Cubed voice sounder message set: 1, bell tone; 2, female emergency evacuation with Signal 3; 3, female announcement to await instructions with Signal 1; 4, female test announcement; 5, male fire alarm evacuation with Signal 2. |
| EN 54-3 Annex C | Message 3 (with Signal 1) and Message 5 (with Signal 2) are approved to EN 54-3 Annex C |
| Message and attention tone period | S-Cubed voice sounders: default period 10 seconds, adjustable up to 30 seconds with the commissioning tool. Audio and bell-tone storage is up to 20 seconds. |
| Volume and message selection | For S-Cubed voice sounders, the S3-CONTROL infrared remote selects tone, speech message and volume from up to 3m away while the panel is in test mode. Hold the remote's power button to store the device settings. After a volume adjustment, save the new level at the panel. |
| Body colour | Red body RAL 3020 |
| Material and flammability | S-Cubed indoor range: polycarbonate body, ABS base; V2 flammability rating. |
| Ingress protection | S-Cubed indoor range: IP 21. |
| Loop operating voltage | S-Cubed indoor range: 35V to 48V. |
|---|---|
| Power source | Loop powered |
| Short circuit isolator, EN 54-17 data | Integral isolator. S-Cubed indoor range limits: Vmax 48V; Vnom 40V; Vmin 24V; VSOmax 16V; VSOmin 8V; ICmax 0.8A; ISmax 1.25A; ILmax 50uA; ZCmax 0.13 ohm. |
| Terminals | S-Cubed indoor range: loop in/out terminals 01, L1, 02 and L2; connect the loop screen to the metal box earth. |
| Temperature and humidity | S-Cubed indoor range: operating temperature -10C to +50C; storage -20C to +70C; relative humidity up to 95% without condensation between +5C and +45C. |
| Dimensions | S-Cubed indoor range: 112mm square face; projection 90mm with the standard base or 75mm with the optional shallow base. |
| Base options | S3-BASE-SR is the optional red shallow base, supplied in packs of five. Indoor S-Cubed wall projection is 90mm with the standard base or 75mm with the shallow base. Fit the earth continuity strap in the deep base. |
| Mounting | Supplied with a matching red standard base and one screw fitted in the base. For indoor S-Cubed installation, secure the base to a flat wall or metal box, with TOP facing upwards. Keep shallow bases at least 10cm below the ceiling for screw access and limit cable tails to 10cm. Keep the enclosure unpainted and the base surface mounted. |
| Commissioning tool | S-Cubed commissioning on Vigilon: Vigilon Commissioning Tool V1.30 or later. |
| Panel software | Gent Vigilon Plus, Compact Plus and Nano addressable systems. |
| Approximate quantity per loop - Gent range datasheet | Approximate maximum quantities for S-Cubed voice sounders are 200 per loop, or 160 with bell sound (dependent on loop load). |
Specifications per manufacturer documentation, subject to change. E&OE.
Standards and approvals
| Standard | What it covers |
|---|---|
| LPCB approved | Approved by the Loss Prevention Certification Board for fire detection and alarm system products. |
| EN 54-3:2001 + A1:2002 + A2:2006 | |
| EN 54-17:2005 + AC:2007 | |
| Declaration of Performance 084-CPR-2014 Issue 3 |
Approval body: Loss Prevention Certification Board (BRE Global Limited), System 1.
Documents
| Document | Type | Size | Download |
|---|---|---|---|
| Installation manual (S3-BASE-SR, S3-BASE-SW, S3-S-VAD-HPR-R, S3-S-VAD-HPR-W, S3-S-VAD-LPR-R, S3-S-W, S3-V-R, S3-V-VAD-HPR-R, S3-V-VAD-HPW-R, S3-V-W, S3-VAD-HPR-R) | Installation | 740 KB | Download PDF |
Optional accessories
- S3-CONTROLHandiLink IR Remote Control for the S-Cubed Range of SoundersRemote Control (S3-CONTROL) for IR volume control£107.64ex VAT£129.17 inc VATIn stock
FAQs
Which speech messages are stored in the S3-V-R, and which meet EN 54-3 Annex C?
S-Cubed voice sounders store four spoken messages and a bell tone. Message 1 is the bell tone. Message 2 is female emergency evacuation with Signal 3. Message 3 is a female announcement to await instructions, with Signal 1. Message 4 is a female test announcement. Message 5 is male fire alarm evacuation with Signal 2. The Message 3 and Signal 1 combination and the Message 5 and Signal 2 combination are approved to EN 54-3 Annex C.
Does the S3-V-R have a beacon, and what do I order if I need one?
The S3-V-R provides tones and spoken alarms without a visual alarm device. It meets EN 54-3 and EN 54-17 and has an integral short circuit isolator. The S3-V-VAD-HPR-R combines voice sounder functions with a High Power red beacon on a red body. The S3-V-W provides voice sounder functions on a white body without a beacon. This S3-V-R has a red body and stores four spoken messages and a bell tone, as well as providing three alarm tones.
How many S3-V-R can go on one Gent loop?
The approximate maximum for S-Cubed voice sounders is 200 per loop, or 160 when using the bell sound, dependent on loop load. Use the Gent Battery Standby and Loop Load Calculator for system design. The indoor S-Cubed range uses a 35V to 48V loop supply and loop in and loop out connections. The loop screen connects to the metal box earth. The S3-V-R has an integral short circuit isolator meeting EN 54-17 and provides tones and spoken alarms.
What is the difference between the standard base and the S3-BASE-SR shallow base?
Supplied with a matching red standard base and one screw fitted in the base. The S3-BASE-SR is the optional red shallow base, supplied in packs of five, for a lower profile. Indoor S-Cubed devices have a 112mm square face and project 90mm from the wall on the standard base or 75mm on the shallow base. Leave at least 10cm below the ceiling when fitting a shallow base so that the locking screw remains accessible. A supplied self tapping screw secures the shallow base assembly. The red finish matches the S3-V-R body.
What does a speech circuit fault reported against an S3-V-R mean?
A speech circuit fault indicates a hardware problem in a device with spoken messages. Replace the affected device. Tone, stored message and volume are set during commissioning, and the S3-CONTROL infrared remote can also change these settings on site. Use the remote within 3m with the panel in test mode. Holding its power button saves the settings to the device; store any volume change at the control panel as well. The S3-V-R has four spoken messages and a bell tone, with no visual alarm device.
Also in this range
- S3-V-WS3 Voice Sounder White BodyThe same S-Cubed Mark 3 voice sounder on a white body, RAL 9010, designated by the manufacturer 'S3 Voice Sounder/White Body'. Same tones, same five speech messages, same declaration route (DoP 084-CPR-2014 covers both). Stocked at GBP 90.30 ex VAT.£90.30ex VAT£108.36 inc VATIn stock
- S3-V-VAD-HPR-RS3 red Body Voice Sounder High Power red VADThe same voice sounder on the same red body with an integral High Power red visual alarm device added, declared to EN 54-23 as well as EN 54-3 and EN 54-17. The part to specify where visual coverage is required rather than audible alarm alone. Stocked at GBP 126.78 ex VAT. Note there is no Environmentally Protected voice sounder WITHOUT a beacon anywhere in the range, so an outdoor position has no direct equivalent of the S3-V-R.£126.78ex VAT£152.14 inc VATIn stock