Skip to content

Trade prices shown ex VAT. Order by 3pm for same-day dispatch on stocked lines, UK mainland. Free UK delivery on orders over £250 ex VAT.

Part Number or the Week S3EP-V-VAD-HPR-R

Gent S3 Sounder red Body

Part no.S3-S-R
BrandGent
RangeS3 Sounders & VADs
Sub-rangeWall Sounders
Gent by Honeywell S3 Sounder red Body — main product photo

Image for illustration; item supplied may differ

At a glance

  • S-Cubed Mark 3 tone sounderA red bodied wall tone sounder for Gent Vigilon Plus, Compact Plus and Nano addressable systems. This model has no visual alarm device.
  • Three S-Cubed alarm tonesS-Cubed sounders provide three LPCB approved signals: an intermittent 970Hz tone at 1Hz, alternating 730Hz and 970Hz tones at 2Hz, and a continuous 970Hz tone. Each tone frequency has a tolerance of +/-10%. The range sounder rating is 103dB(A) +/-3dB, measured at 90 degrees and 1m.
  • Loop powered with an integral isolatorThe S3-S-R has an integral short circuit isolator meeting EN 54-17. The indoor S-Cubed range uses a 35V to 48V loop supply and loop in/out connections.
  • S-Cubed tone and volume adjustmentFor S-Cubed sounders, the S3-CONTROL infrared remote selects tone and volume from up to 3m away while the panel is in test mode. Hold the remote's power button to store the device settings. After a volume adjustment, save the new level at the panel.
  • Indoor S-Cubed housing and base optionsThe indoor S-Cubed range is rated IP 21, with a 112mm square face and wall projection of 90mm on the standard base or 75mm on the optional shallow base. The S3-BASE-SR shallow base is red and comes in packs of five.
  • EN 54-3 sounder and EN 54-17 isolatorThis tone sounder meets EN 54-3 and has a short circuit isolator meeting EN 54-17. It provides tone alarms without spoken messages.

Description

The Gent S3-S-R is a red bodied wall tone sounder in the S-Cubed Mark 3 range, for Gent Vigilon Plus, Compact Plus and Nano addressable systems. It provides three alarm tones: intermittent, alternating and continuous. This model has no spoken messages or visual alarm device. It is loop powered and has an integral short circuit isolator. The indoor S-Cubed range is rated IP 21 for internal walls. Tone and volume can be set with the commissioning tool or S3-CONTROL infrared remote. The matching S3-BASE-SR shallow base is optional. The indoor range has a 112mm square face and projects 90mm on the standard base or 75mm on the optional shallow base. Supplied with a matching red standard base and one screw fitted in the base.

The S3-S-R is the red bodied tone sounder in Gent's S-Cubed Mark 3 range. It is loop powered and compatible with Gent Vigilon Plus, Compact Plus and Nano systems. It provides tone alarms without spoken messages.

Read the full technical description

The S3-S-R is the red bodied tone sounder in Gent's S-Cubed Mark 3 range. It is loop powered and compatible with Gent Vigilon Plus, Compact Plus and Nano systems. It provides tone alarms without spoken messages.

S-Cubed sounders provide three LPCB approved signals: an intermittent 970Hz tone at 1Hz, alternating 730Hz and 970Hz tones at 2Hz, and a continuous 970Hz tone. Each tone frequency has a tolerance of +/-10%. The range sounder rating is 103dB(A) +/-3dB, measured at 90 degrees and 1m.

The indoor S-Cubed range uses a 35V to 48V loop supply and loop in/out terminals 01, L1, 02 and L2; the loop screen connects to the metal box earth. The S3-S-R has an integral short circuit isolator meeting EN 54-17. The indoor range is rated IP 21 for internal wall positions. Its body is polycarbonate and the base is ABS. The indoor S-Cubed range has a 112mm square face and projects 90mm on the standard base or 75mm on an optional shallow base. The S3-BASE-SR shallow base matches this red body and comes in packs of five. Allow at least 10cm below the ceiling when fitting a shallow base so that the locking screw remains accessible. Keep the TOP mark facing upwards and the cable tails within 10cm. The base must remain surface mounted and the enclosure unpainted.

Vigilon commissioning uses the Vigilon Commissioning Tool V1.30 or later. For S-Cubed sounders, the S3-CONTROL infrared remote selects tone and volume from up to 3m away while the panel is in test mode. Hold the remote's power button to store the device settings. After a volume adjustment, save the new level at the panel. S-Cubed sounders and visual alarm devices synchronise across all loops of one panel; synchronisation does not extend across a network of panels.

Specifications

Manufacturer's designationS3 Sounder/Red Body
Device typeWall mounted tone sounder in the Gent S-Cubed Mark 3 range, for indoor positions
Sound outputS-Cubed sounder range rating: 103dB(A) +/-3dB at 90 degrees and 1m.
TonesS-Cubed sounder signals: 1, intermittent 970Hz at 1Hz; 2, alternating 730Hz and 970Hz at 2Hz; 3, continuous 970Hz. Tone frequencies have a +/-10% tolerance. All three signals are LPCB approved.
Voice messagesNo spoken messages.
Visual alarm deviceNone fitted
Power sourceLoop powered
Loop operating voltageS-Cubed indoor range: 35V to 48V.
TerminalsS-Cubed indoor range: loop in/out terminals 01, L1, 02 and L2; connect the loop screen to the metal box earth.
Short circuit isolator, EN 54-17 dataIntegral isolator. S-Cubed indoor range limits: Vmax 48V; Vnom 40V; Vmin 24V; VSOmax 16V; VSOmin 8V; ICmax 0.8A; ISmax 1.25A; ILmax 50uA; ZCmax 0.13 ohm.
Approximate quantity per loop - Gent range datasheetThe approximate maximum quantity for S-Cubed standard tone sounders is 200 per loop (dependent on loop load).
Volume and tone selectionFor S-Cubed sounders, the S3-CONTROL infrared remote selects tone and volume from up to 3m away while the panel is in test mode. Hold the remote's power button to store the device settings. After a volume adjustment, save the new level at the panel.
Commissioning toolS-Cubed commissioning on Vigilon: Vigilon Commissioning Tool V1.30 or later.
Panel compatibilityGent Vigilon Plus, Compact Plus and Nano addressable systems.
Ingress protectionS-Cubed indoor range: IP 21.
ApplicationS-Cubed indoor range: internal wall positions.
Body colourRed body RAL 3020
Material and flammabilityS-Cubed indoor range: polycarbonate body, ABS base; V2 flammability rating.
Temperature and humidityS-Cubed indoor range: operating temperature -10C to +50C; storage -20C to +70C; relative humidity up to 95% without condensation between +5C and +45C.
DimensionsS-Cubed indoor range: 112mm square face; projection 90mm with the standard base or 75mm with the optional shallow base.
Base optionsS3-BASE-SR is the optional red shallow base, supplied in packs of five. Indoor S-Cubed wall projection is 90mm with the standard base or 75mm with the shallow base. Fit the earth continuity strap in the deep base.
MountingSupplied with a matching red standard base and one screw fitted in the base. For indoor S-Cubed installation, secure the base to a flat wall or metal box, with TOP facing upwards. Keep shallow bases at least 10cm below the ceiling for screw access and limit cable tails to 10cm. Keep the enclosure unpainted and the base surface mounted.
Siting guidanceTest S-Cubed sound levels in the protected areas against the site requirements.

Specifications per manufacturer documentation, subject to change. E&OE.

Standards and approvals

StandardWhat it covers
LPCB approvedApproved by the Loss Prevention Certification Board for fire detection and alarm system products.
EN 54-3:2001 + A1:2002 + A2:2006
EN 54-17:2005 + AC:2007
Declaration of Performance 083-CPR-2014 Issue 3

Approval body: Loss Prevention Certification Board (BRE Global Limited), System 1.

Documents

DocumentTypeSizeDownload
s3 mk3 installInstallation740 KBDownload PDF

Optional accessories

FAQs

Does the S3-S-R have a flashing beacon?

No. The S3-S-R provides tone alarms without a visual alarm device or spoken messages. Its sounder meets EN 54-3 and its integral short circuit isolator meets EN 54-17. The S3-S-VAD-HPR-R combines a tone sounder and High Power red beacon on a red body; the S3-S-VAD-HPR-W combines those functions on a white body. The S3-VAD-HPR-R is a beacon without a sounder. The S3-V-R is a red bodied voice sounder with four spoken messages and a bell tone.

What is the difference between the S3-S-R and the S3-V-R?

Both models are red bodied wall sounders in the S-Cubed range, with three alarm tones and integral short circuit isolators. The S3-V-R also stores four spoken messages and a bell tone. The S3-S-R provides tones without spoken messages. Across the S-Cubed sounder range, tone and volume can be adjusted with the commissioning tool or the S3-CONTROL infrared remote. Use the remote within 3m while the panel is in test mode, then save any adjusted volume at the panel.

What is the S3-BASE-SR shallow base, and when would I use one?

Supplied with a matching red standard base and one screw fitted in the base. The S3-BASE-SR is an optional red shallow base, supplied in packs of five. It provides a lower profile for the red bodied S3-S-R. Indoor S-Cubed devices project 90mm from the wall on the standard base or 75mm on the shallow base. Leave at least 10cm below the ceiling when installing a shallow base so that its locking screw remains accessible. The shallow base has one cable entry point, and a supplied self tapping screw secures the assembly.

Can the S3-S-R be mounted outdoors?

The S3-S-R is an indoor sounder for internal wall positions. The indoor S-Cubed range has an IP 21 rating and is unsuitable for external wall mounting. Its face is 112mm square, with a wall projection of 90mm on the standard base or 75mm on the optional shallow base. The red S3-BASE-SR shallow base matches this red bodied sounder. Keep the enclosure unpainted and the base surface mounted, with the TOP marking facing upwards and cable tails no longer than 10cm.

How many S3-S-R sounders can go on one loop?

The approximate maximum for S-Cubed standard tone sounders is 200 per loop, dependent on loop load. Use the Gent Battery Standby and Loop Load Calculator for system design. The indoor S-Cubed range uses a 35V to 48V loop supply, with loop in and loop out connections and the loop screen connected to the metal box earth. The S3-S-R has an integral short circuit isolator meeting EN 54-17. This model provides three tones, without speech or a beacon.

Also in this range

  • S3-S-WS3 Sounder White BodyThe same tone sounder on a white body, RAL 9010, instead of red. Same three tones, the same 103dB(A) +/-3dB 90 degrees at 1m sound level, the same loop connection and the same EN 54-3 and EN 54-17 declaration under the same Declaration of Performance (083-CPR-2014 Issue 3, its own certificate number). Choose on the finish the specification calls for; with the white body the matching lower profile base is the S3-BASE-SW.£75.35ex VAT£90.42 inc VATIn stock
  • S3EP-S-RS3 EP (IP66) Sounder red BodyThe environmentally protected version of the same red bodied tone sounder, for outdoor positions and harsh internal areas. The S3-S-R is an indoor unit that Gent rates IP 21 and instructs is not mounted on an external wall surface. The EP unit has its own installation instructions and a larger enclosure, 125 x 125 x 95mm against 112mm square by 90mm on the standard base.£114.22ex VAT£137.06 inc VATIn stock