Surface Mount Sampling Point · VESDA VEA
Xtralis VSP-983-B22 VEA 4mm Surface Point x22
- Type
- Surface Mount Sampling Point
- Inlet size
- 4mm
- Pack quantity
- pack of 22
- Ordering code
- VSP-983-B22
- Supervision
- Full supervision — each patented VEA sampling point and microbore tube is fully supervised by the detector
- Cleaning
- Automated cleaning by the detector
- Tube orientation
- Swivel joint to allow optimum tube orientation
Overview
What it is and how it fits the system.
The Xtralis VSP-983-B22 supplies the black 4mm surface-mount sampling point for the VESDA-E VEA aspirating smoke detection series in a pack of 22, designed for use where access to the ceiling void is limited. Screwed directly to the ceiling with microbore tubes run along the surface, each patented sampling point is fully supervised, automatically cleaned by the detector, and fitted with a swivel joint for optimum tube orientation.
Technical overview
VSP-983-B22 orders the black 4mm surface-mount sampling point for Xtralis VESDA-E VEA aspirating smoke detectors in a pack of 22. Documented host units for these points are the VEA-040-A00, a VEA-40 detector with LEDs, and the VEA-040-A10 carrying a 3.5 inch display.
Points of this type fasten with screws to the ceiling itself, and the 4mm microbore tubing then follows the ceiling in plain sight through the protected area — the configuration provided for ceilings whose voids offer limited access.
Behind each patented head, supervision runs back to the detector covering both the point and its tube, cleaning happens automatically from the detector, and a swivel joint absorbs whatever tube angle the installation calls for. The VSP-978 head removal key and the sampling point retainer are referenced in the same ordering information.
Specifications
Full technical data for this part.
| Type | Surface Mount Sampling Point |
|---|---|
| Inlet size | 4mm |
| Colour | Black |
| Pack quantity | pack of 22 |
| Ordering code | VSP-983-B22 |
| Supervision | Full supervision — each patented VEA sampling point and microbore tube is fully supervised by the detector |
| Cleaning | Automated cleaning by the detector |
| Tube orientation | Swivel joint to allow optimum tube orientation |
| Mounting | Surface mount sampling points are screwed directly to the ceiling; microbore tubes are run along the ceiling, visible in the protected area |
| Application use case | Designed for use where access to the ceiling void is limited |
Specifications sourced from manufacturer documentation.
Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know
Optional accessories
Optional additions — this product works without them.
VEA Sample Point Head Removal Key
VSP-978 VESDA-E VEA Sample Point Head Removal Key (listed in ordering information)
VESDA-E VEA-40 Det with LEDs
VEA series detector this sampling point is used with
VESDA-E VEA-40 Det with 3.5" Display
VEA series detector this sampling point is used with
Datasheets & documents