Gent Spare PCB for S4 Mains Powered Interface - 2.5A (S4-34440-12)

Part no.VSINTM-PCB12
BrandGent
RangeS4 Interfaces & Accessories
Sub-rangeInterface Spares
Gent VSINTM-PCB12 Mains Powered Interface Board — green PCB with terminal blocks and black power module.

Image for illustration; item supplied may differ

At a glance

  • Spare circuit boardReplacement PCB for the Gent S4-34440-12 mains powered interface.
  • For the 2.5 A parent interfaceThe S4-34440-12 has a maximum total output current of 2.5 A.
  • Four-channel parent rangeThe S4 mains powered interfaces have four configurable input/output channels.
  • Terminal blocks transferThe existing wired terminal blocks fit onto the replacement board.
  • Original earthing fixingsReuse the board fixing screws as part of the case earth connection.
  • Configuration after fittingAllocate the loop, then configure and test the installed interface for the site.

Description

The Gent VSINTM-PCB12 is a spare circuit board for the S4-34440-12 mains powered interface, the 2.5 A version. It replaces the original board inside the existing interface. The wired terminal blocks transfer to the new board, and the original fixing screws are reused as part of the case earth connection. Before removal, stop the loop at the fire panel, isolate the mains supply and disconnect the battery. After fitting, refit the protective cover and reconnect the mains and battery supplies, then allocate the loop. The interface must be configured and tested for the site after the board has been replaced.

The VSINTM-PCB12 fits the Gent S4-34440-12. The S4-34440-12 has a maximum total output current of 2.5 A. The S4 mains powered interface range has four channels that can be set for inputs, outputs or both.

Read the full technical description

The VSINTM-PCB12 fits the Gent S4-34440-12. The S4-34440-12 has a maximum total output current of 2.5 A. The S4 mains powered interface range has four channels that can be set for inputs, outputs or both.

During board replacement, the existing wired terminal blocks transfer to the new board. Reuse the original board fixing screws, which provide part of the case earth connection. Stop the loop, isolate the mains supply and disconnect the battery before removing the board.

Refit the protective cover before reconnecting mains at P3, followed by the battery lead at P7. Allocate the loop, close and lock the enclosure, then configure and test the interface. For the S4-34440-12, select the mains powered interface type and set its channels in the S4-MP configuration page.

Specifications

BrandGent
Part numberVSINTM-PCB12
Part typeSpare printed circuit board
FitsS4-34440-12
Parent interface typeS4 mains powered interface
Parent maximum total output current2.5 A
Parent range channel count4 configurable input/output channels
Replacement terminal connectionsTransfer the existing wired terminal blocks
Board fixing screwsOriginal screws reused; part of case earthing

Specifications per manufacturer documentation, subject to change. E&OE.

Documents

DocumentTypeSizeDownload
Installation manual (VSINTM-PCB02, VSINTM-PCB12)Installation81 KBDownload PDF

Optional accessories

FAQs

Which interface does the VSINTM-PCB12 fit?

The VSINTM-PCB12 is the spare circuit board for the Gent S4-34440-12, which has a maximum total output current of 2.5 A. The S4 mains powered interface range has four channels for input and output functions, including using input and output circuits together on a channel. When configuring the S4-34440-12, select the mains powered interface type and set the required channel functions in the S4-MP page. These settings apply to the installed interface.

What is involved in replacing the VSINTM-PCB12?

Stop the loop at the fire panel, isolate the mains and disconnect the battery before removing the existing board. Retain the fixing screws and use them to secure the replacement; they form part of the case earthing. Transfer the wired terminal blocks and refit the protective cover. Reconnect the mains at P3, followed by the battery lead at P7, then allocate the loop. Close and lock the enclosure, and configure and test the interface for the site.