VESDA Metal Box HLI - Master-Slave

Part no.VHX-1310
BrandVESDA
RangeVESDA Programming and Connectivity
VESDA VHX-1310 Wall-Mounted Master-Slave HLI — grey-topped rectangular unit with black base, angled view.

Image for illustration; item supplied may differ

At a glance

  • Polled Master-Slave InterfaceVHX-1310 is an Open Protocol HLI (Master-Slave) in wall-mounted form.
  • Single Answer Per PollIn response to polling by the host, the HLI generates a single response which is sent back to the host.
  • No Unsolicited MessagesNo unsolicited messages are sent from the HLI to the host.
  • Fault Status ReportingFault Status covers System, Zone, Urgent, Power, Network, Flow and Filter conditions.
  • ASCII Fault StringsFault strings are ASCII strings to describe each fault code.
  • Detector ControlsDetector controls are Reset, Isolate, Silence, Test, Scan and Normalize, the last being master-slave only.
  • Day And Night ThresholdsConfiguration of Day and Night alarm thresholds is a master-slave only function.

Description

In the master-slave model the host asks, the HLI answers once, and nothing is raised in between.

Alongside the fault detail, VHX-1310 makes Day and Night alarm threshold configuration available, a function that belongs to the master-slave models only. The unit is wall-mounted.

Wall-mounted and master-slave, VHX-1310 is an Open Protocol HLI in the VESDA range. Communication is host-driven: in response to polling by the host, the HLI generates a single response which is sent back to the host, and in this way, no unsolicited messages are sent from the HLI to the host.

Fault Status reported to the host covers System, Zone, Urgent, Power, Network, Flow and Filter conditions, and fault strings - ASCII strings to describe each fault code - accompany them.

Read the full technical description

Secondary monitoring of fire alarms and of other notifications is the recommended VESDA HLI duty, and the interface is also suitable where primary reporting to a fire panel is required. If it is to carry primary reporting, it must first be integrated with the receiving fire panel or primary reporting system and approved or listed with that system, to the fire standards and codes in force.

Wall-mounted and master-slave, VHX-1310 is an Open Protocol HLI in the VESDA range. Communication is host-driven: in response to polling by the host, the HLI generates a single response which is sent back to the host, and in this way, no unsolicited messages are sent from the HLI to the host.

Fault Status reported to the host covers System, Zone, Urgent, Power, Network, Flow and Filter conditions, and fault strings - ASCII strings to describe each fault code - accompany them.

Detector controls available are Reset, Isolate, Silence, Test, Scan and Normalize, the last of these being a master-slave only function, as is configuration of Day and Night alarm thresholds. VESDAnet is a propriety protocol allowing an Xtralis VESDA range of devices to talk on one network, and it is fault tolerant in both directions. Recommended practice keeps a VESDA HLI on secondary monitoring of fire alarms and of the other notifications a VESDAnet produces; primary reporting is suitable as well, though the interface must then be approved or listed with, and integrated into, the panel or reporting system taking that duty, for the relevant fire standards and codes.

Specifications

Ordering code descriptionOpen Protocol HLI (Master-Slave) / Wall-mounted Open Protocol HLI (Master-Slave)
Operating modelMaster-Slave only
Supply voltage24 VDC
Current consumption70 mA (Quiescent)
Power consumption1.68 W (Quiescent)
Dimensions280 mm x 185 mm x 55 mm (11 in. x 7.3 in. x 2.2 in. approx.)
Weight2 kg (4.4 lbs)
Mounting pointØ 6.5mm
Number of detectors supportedUp to 40 detectors* (If your network has more than 40 detectors, please contact your Xtralis representative.)
Modem supportModem support is not available
Supplied withVESDAlink RS-232 9-way serial cable (male-female) (identical to VSP-509)
MountingConvenient wall-mounted design
Information availableDetector Type (VLC, VLS, VLP, VLF); Support Mimic Mode: VLP/VLC/VLS; Alarm status (Alert, Action, Fire1 & Fire2); Fault Status (System, Zone, Urgent, Power, Network, Flow, Filter); Status (Isolated, Normalizing, AutoLearn, Scanning)