VESDA Metal Box HLI - Master-Slave
| Part no. | VHX-1310 |
|---|---|
| Brand | VESDA |
| Range | VESDA Programming and Connectivity |

Image for illustration; item supplied may differ
At a glance
- Polled Master-Slave InterfaceVHX-1310 is an Open Protocol HLI (Master-Slave) in wall-mounted form.
- Single Answer Per PollIn response to polling by the host, the HLI generates a single response which is sent back to the host.
- No Unsolicited MessagesNo unsolicited messages are sent from the HLI to the host.
- Fault Status ReportingFault Status covers System, Zone, Urgent, Power, Network, Flow and Filter conditions.
- ASCII Fault StringsFault strings are ASCII strings to describe each fault code.
- Detector ControlsDetector controls are Reset, Isolate, Silence, Test, Scan and Normalize, the last being master-slave only.
- Day And Night ThresholdsConfiguration of Day and Night alarm thresholds is a master-slave only function.
Description
In the master-slave model the host asks, the HLI answers once, and nothing is raised in between.
Alongside the fault detail, VHX-1310 makes Day and Night alarm threshold configuration available, a function that belongs to the master-slave models only. The unit is wall-mounted.
Wall-mounted and master-slave, VHX-1310 is an Open Protocol HLI in the VESDA range. Communication is host-driven: in response to polling by the host, the HLI generates a single response which is sent back to the host, and in this way, no unsolicited messages are sent from the HLI to the host.
Fault Status reported to the host covers System, Zone, Urgent, Power, Network, Flow and Filter conditions, and fault strings - ASCII strings to describe each fault code - accompany them.
Read the full technical description
Secondary monitoring of fire alarms and of other notifications is the recommended VESDA HLI duty, and the interface is also suitable where primary reporting to a fire panel is required. If it is to carry primary reporting, it must first be integrated with the receiving fire panel or primary reporting system and approved or listed with that system, to the fire standards and codes in force.
Wall-mounted and master-slave, VHX-1310 is an Open Protocol HLI in the VESDA range. Communication is host-driven: in response to polling by the host, the HLI generates a single response which is sent back to the host, and in this way, no unsolicited messages are sent from the HLI to the host.
Fault Status reported to the host covers System, Zone, Urgent, Power, Network, Flow and Filter conditions, and fault strings - ASCII strings to describe each fault code - accompany them.
Detector controls available are Reset, Isolate, Silence, Test, Scan and Normalize, the last of these being a master-slave only function, as is configuration of Day and Night alarm thresholds. VESDAnet is a propriety protocol allowing an Xtralis VESDA range of devices to talk on one network, and it is fault tolerant in both directions. Recommended practice keeps a VESDA HLI on secondary monitoring of fire alarms and of the other notifications a VESDAnet produces; primary reporting is suitable as well, though the interface must then be approved or listed with, and integrated into, the panel or reporting system taking that duty, for the relevant fire standards and codes.
Specifications
| Ordering code description | Open Protocol HLI (Master-Slave) / Wall-mounted Open Protocol HLI (Master-Slave) |
|---|---|
| Operating model | Master-Slave only |
| Supply voltage | 24 VDC |
| Current consumption | 70 mA (Quiescent) |
| Power consumption | 1.68 W (Quiescent) |
| Dimensions | 280 mm x 185 mm x 55 mm (11 in. x 7.3 in. x 2.2 in. approx.) |
| Weight | 2 kg (4.4 lbs) |
| Mounting point | Ø 6.5mm |
|---|---|
| Number of detectors supported | Up to 40 detectors* (If your network has more than 40 detectors, please contact your Xtralis representative.) |
| Modem support | Modem support is not available |
| Supplied with | VESDAlink RS-232 9-way serial cable (male-female) (identical to VSP-509) |
| Mounting | Convenient wall-mounted design |
| Information available | Detector Type (VLC, VLS, VLP, VLF); Support Mimic Mode: VLP/VLC/VLS; Alarm status (Alert, Action, Fire1 & Fire2); Fault Status (System, Zone, Urgent, Power, Network, Flow, Filter); Status (Isolated, Normalizing, AutoLearn, Scanning) |
Specifications per manufacturer documentation, subject to change. E&OE.
Optional accessories
- VHX-1300Metal Box HLI - Peer to PeerAlternative - the peer-to-peer model of the same wall-mounted Open Protocol HLI.£2,606.48ex VAT£3,127.78 inc VATIn stock
Spares & replacement parts
- VSP-509LaserCOMPACT RO 9 Pin LeadSupplied with VESDAlink RS-232 9-way serial cable (male-female), identical to VSP-509 (VES£77.63ex VAT£93.16 inc VATIn stock