VESDA VHX-1300 Wall-Mounted Peer-to-Peer HLI — grey enclosure with blue VESDA logo, side vents and front D-sub connector.

Image for illustration; item supplied may differ

At a glance

  • Wall-Mounted Peer-To-Peer HLIVHX-1300 is the wall-mounted Open Protocol HLI (Peer-to-Peer).
  • Built-In VESDAnet InterfaceA built-in VESDAnet interface means a remote VESDAnet socket module is not needed.
  • Two-Way Link SupervisionBoth the HLI and host are responsible for supervising the communications link between them.
  • Unsolicited Host MessagesThe HLI sends unsolicited messages to the host while the host polls it for information about devices on VESDAnet.
  • Multiple Message RequestsIn the peer-to-peer model, the host can request and receive multiple messages from the HLI.
  • Display Information ReportedDisplay info covers alarm thresholds and location name, and display update carries smoke level with alarm and fault status.
  • Mimic Mode SupportMimic Mode is supported for VLP/VLC/VLS.

Description

Two-way supervision is the distinguishing feature here. Because the HLI raises messages of its own rather than waiting to be asked, the communications link is watched from both ends.

Detector Type (VLC, VLS, VLP, VLF) on VESDAnet is reported back to the host. The unit is wall-mounted and carries the VESDAnet interface on board.

VHX-1300 is the wall-mounted Open Protocol HLI (Peer-to-Peer) in the VESDA range, connecting a VESDAnet to the host - PC software monitoring tools, a Building Management System (BMS) or a Fire Alarm Control Panel (FACP). A built-in VESDAnet interface means a remote VESDAnet socket module is not needed.

In the peer-to-peer model, the host polls the HLI for information about devices on VESDAnet, while the HLI sends unsolicited messages to the host, so both the HLI and host are responsible for supervising the communications link between them. The host can also request and receive multiple messages from the HLI.

Read the full technical description

Secondary monitoring of fire alarms and other VESDAnet notifications is the recommended duty for VESDA HLIs, which are also suitable for primary reporting, whether to the fire panel or to another primary reporting system. Primary reporting requires the unit to be approved or listed with the receiving panel or system, and integrated into it, for the applicable fire standards and codes.

VHX-1300 is the wall-mounted Open Protocol HLI (Peer-to-Peer) in the VESDA range, connecting a VESDAnet to the host - PC software monitoring tools, a Building Management System (BMS) or a Fire Alarm Control Panel (FACP). A built-in VESDAnet interface means a remote VESDAnet socket module is not needed.

In the peer-to-peer model, the host polls the HLI for information about devices on VESDAnet, while the HLI sends unsolicited messages to the host, so both the HLI and host are responsible for supervising the communications link between them. The host can also request and receive multiple messages from the HLI.

Direct access and monitoring of your entire VESDAnet system is what the interface provides. Display info covers alarm thresholds and location name, display update carries smoke level with alarm and fault status, and Mimic Mode is supported for VLP/VLC/VLS. For a VESDA HLI the recommended application is secondary monitoring of fire alarms and other VESDAnet notifications; it is also suitable for primary reporting, whether that goes to a fire panel or to another primary reporting system, provided the unit has first been integrated with that panel or system and approved or listed with it, under the fire standards and codes that govern the installation.

Specifications

Ordering codeVHX-1300
DescriptionOpen Protocol HLI (Peer-to-Peer) / Wall-mounted Open Protocol HLI (Peer-to-Peer)
Operating modePeer-to-Peer - the host polls the HLI for information about devices on VESDAnet, while the HLI sends unsolicited messages to the host; both the HLI and host are responsible for supervising the communications link
Power consumption1.68 W (Quiescent)
Supply voltage24 VDC
Current consumption70 mA (Quiescent)
Dimensions280 mm x 185 mm x 55 mm (11 in. x 7.3 in. x 2.2 in. approx.)
Weight2 kg (4.4 lbs)
Mounting pointØ 6.5mm
Supplied withVESDAlink RS-232 9-way serial cable (male-female) (identical to VSP-509)
Number of detectors supportedUp to 40 detectors* (If your network has more than 40 detectors, please contact your Xtralis representative)
Modem supportModem support is not available
InterfaceBuilt-in VESDAnet interface
Configuration softwareEasily configured using Xtralis configuring and monitoring software packages