VESDA Conventional Reflective Beam. Uses the same accessories as the 6500 conventional beams. Please see conventional section to find these accessories

Part no.OSI-RE-SS
BrandVESDA
RangeBeam Detection OSID Range
Sub-rangeBeam Detection
OSID OSI-RE-SS Reflective Beam Smoke Detector — white unit with circular lens and three indicator lights.

Image for illustration; item supplied may differ

Description

The OSI-RE-SS is a reflective beam smoke detection system comprising an Imager and a reflector. It operates from 10.2 to 32 VDC (12 or 24 VDC nominal) with the reflector positioned between 5 m minimum and 100 m maximum from the Imager, and offers four selectable obscuration settings from 25% to 50%. A normal commissioning process takes roughly 10 seconds, and the unit must be powered from an EN54-4 certified AC/DC power converter.

OSI-RE-SS is a conventional reflective beam smoke detection system in the OSID beam detection range, built as a two-part pairing of an Imager and a reflector. Spans between the two parts run from 5 m at minimum out to 100 m, and the part supersedes the earlier 6500RE and 6500RSE.

Read the full technical description

OSI-RE-SS is a conventional reflective beam smoke detection system in the OSID beam detection range, built as a two-part pairing of an Imager and a reflector. Spans between the two parts run from 5 m at minimum out to 100 m, and the part supersedes the earlier 6500RE and 6500RSE.

A normal commissioning pass completes in roughly 10 seconds, and four selectable obscuration settings spanning 25% to 50% allow the response to be matched to the space. On the hardware side, the unit carries a heater with an on/off switch, a USB connector and support for Class A return loop wiring, alongside separate alarm and fault relay connections plus remote outputs for alarm and trouble and a remote test/reset input.

Fire alarm control panel interfacing is supported, analogue addressable input or zone modules can be used with the system, and a listed end-of-line power supervision module is required when other sensors share the loop. For setting to work, the OSP-002 laser alignment tool assists rough alignment over longer distances or in heavily lit spaces, the OSP-004 test filter checks correct alarming at the reflector, and the RTS151KEY remote test station handles testing; the 6500-LRK long range reflector kit covers 70 m to 100 m spans, and the 6500-MMK adds ceiling and wall mount swivel brackets. CE compliance requires power from EN54-4 certified AC/DC power converters.

Specifications

Wire gauge for terminals22 AWG (0.64 mm, 0.34 mm 2 ) to 14 AWG (1.6 mm, 2.08 mm 2 )
Operating voltage range10.2 to 32 VDC (12 or 24VDC nominal)
Maximum standby current7 mA @ 32 VDC, 11 mA @ 24 VDC, 20 mA @ 12 VDC, 50 mA @ 10.2 VDC
Maximum alarm current (led on)11 mA @ 32... (value truncated in source)
Power source / compliance requirementThe products shall be powered from a EN54-4 certified AC/DC Power converters to be in compliance for CE certification.
Reflector min/max distance from imager16 ft. (5m) minimum 328 ft. (100m) maximum
Heater on/off switchNo heater / Heater ON (heater on/off switch present)
Commissioning timeA normal commissioning process takes roughly 10 seconds.
Sensitivity/obscuration settings (yellow blink key)1 blink = 25%, 2 blinks = 30%, 3 blinks = 40%, 4 blinks = 50%
Mounting back box pilot holes5 pilot holes in the backbox
Imager holding screwsloosen the 3 holding screws (to detach Imager from backbox)
End-of-line resistor10k ohm External Resistor / EOL RESISTOR
Back box j-box compatibilityfor 4” J-Box
Usb connectorUSB Connector present

Specifications per manufacturer documentation, subject to change. E&OE.