Beam Detection OSID Range
Xtralis OSI-10 7 Degree OSID Smoke Imager
- Ordering code / part number
- FG-02-029 OSI-10 OSID Imager 7 degree coverage (min 25m)
- Product type / coverage (catalogue cell)
- OSI-10 OSID Imager, 7 degree coverage (min 25m)
- Coverage angle
- 7 degree (7º) coverage
- Maximum detection range
- Maximum detection range of 150 m (492 ft) for the OSI-10
- Field of view + distance + emitter pairing (crib sheet)
- OSI-10 Imager 8° FOV, Distance 30-150 m with OSE-SP-01 and OSE-SPW; 1-on-1 system; the OSI-10 is not suited to work with
- Imager technology
- CMOS chip imager; multiple angle of coverage; ball & socket adjustment
- Commissioning
- Automatic commissioning in under ten minutes
You will also need
Needed to install, power or certify this product.
Emitter - Alkaline Battery
Imager forms a 1-on-1 system with the OSE-SP-01 standard-power emitter
Overview
What it is and how it fits the system.
The Xtralis OSI-10 is the narrow-coverage OSID Imager, the receiving unit of the OSID dual-wavelength projected-beam smoke detection system, using a CMOS imaging chip to image dual-wavelength light from one or more OSID Emitters. It provides 7° coverage with a maximum detection range of 150 m and three selectable alarm thresholds. Supplied under order code FG-02-029, it features ball-and-socket adjustment and automatic commissioning in under ten minutes.
Technical overview
OSI-10 is the Conventional narrow-coverage OSID Imager, the receiving unit of the Xtralis OSID dual-wavelength projected-beam smoke detection system, using a CMOS imaging chip to image dual-wavelength light from one or more OSID Emitters. It provides 7° coverage with a maximum detection range of 150 m and three selectable alarm thresholds. Supplied under order code FG-02-029, it features ball-and-socket adjustment and automatic commissioning in under ten minutes.
The OSI-10 Imager forms a 1-on-1 system with the OSE-SP-01 standard-power emitter and is compatible with OSID Emitters such as OSE-SPW Standard Power/Wired and OSE-HPW High Power/Wired. It supports wiring to the RTS150KEY reset station via either a 3-wire connection or a 4-wire configuration. Environmental protection is available through the OSID-EHI IP66-rated housing and anti-condensation OSEH-ACF accessory.
Specifications
Full technical data for this part.
| Ordering code / part number | FG-02-029 OSI-10 OSID Imager 7 degree coverage (min 25m) |
|---|---|
| Product type / coverage (catalogue cell) | OSI-10 OSID Imager, 7 degree coverage (min 25m) |
| Coverage angle | 7 degree (7º) coverage |
| Maximum detection range | Maximum detection range of 150 m (492 ft) for the OSI-10 |
| Field of view + distance + emitter pairing (crib sheet) | OSI-10 Imager 8° FOV, Distance 30-150 m with OSE-SP-01 and OSE-SPW; 1-on-1 system; the OSI-10 is not suited to work with |
| Imager technology | CMOS chip imager; multiple angle of coverage; ball & socket adjustment |
| Commissioning | Automatic commissioning in under ten minutes |
| Alarm thresholds | Three selectable alarm thresholds |
| Reset-station wiring | Two ways to wire OSI-90 and OSI-10 Imagers to the RTS150KEY: a 3-wire connection (reset switch + Alarm LED) or a 4-wire |
Specifications sourced from manufacturer documentation.
Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know
Optional accessories
Optional additions — this product works without them.
Emitter - Standard Power, Wired
OSE-SP-01 and OSE-SPW Standard Power Emitters - the crib sheet pairs the OSI-10 (8° FOV, 3
Imager - 80º coverage-Imager with an 80° field of view providing distances 6m to 68m. Distances: 6-34m with OSE-SP-01 / OSE-SPW, 12-68m with OSE-HPW, 12-50m with OSE-HP-01. OSI-90 can operate with up to 7 Emitters.
RTS150KEY reset station - the OSI-10 (with the OSI-90) wires to the RTS150KEY via a 3-wire
Imager environmental housing IP66
OSID-EHI Imager Environmental Housing (IP66) - sibling OSID Imager accessory co-listed in
OSID Installation Kit. Kit including: Laser Alignment Tool, Test Filter, PC Cable, Cleaning Cloth, Reflectors and Manual.
OSID-WG Wire Guard and OSID-INST OSID Installation Kit - co-listed OSID accessories in the
Wire Guard. Steel cage to protect OSID Imagers and Emitters from damage.
OSID-WG Wire Guard and OSID-INST OSID Installation Kit - co-listed OSID accessories in the
Emitter - High Power, Alkaline Battery
Emitter - High Power, Wired
OSID IMAGER RESET STATION SURF MT
Imager connects to the RTS151KIT surface-mount reset station (RTS151KEY unit complete with backbox)
FTDI Cable 1.5m. 1.5m cable for connecting a PC to the Imager for use with OSID Diagnostic software. Cable may be extended by a further 20m when using an active USB amplifier.
FTDI cable connects a PC to the imager via the housing's dedicated entry.