System Sensor High Fixed Temperature Thermal BS (78°C) Conventional Detector
| Part no. | 2020HF |
|---|---|
| Brand | System Sensor |
| Range | Conventional Detection Vision Range |
| Sub-range | Detector |

Image for illustration; item supplied may differ
At a glance
- Fixed Temperature Heat DetectionThe 2020HF is a 78ºC Fixed Temperature Heat Detector using a heat element with an ASIC and a static element.
- EN54 Class BS ApprovalApproval is Class BS to EN54 - 5:2000 (Amendment 1), with LPCB and CE approval held.
- Low Standby CurrentMaximum standby current is 75μA @ 24VDC at 25ºC on a 14 to 28VDC (Nominal 24VDC) supply.
- Latching LED IndicationAn integral LED latches on to give a local alarm signal until the detector is reset by a momentary power interruption.
- Ambient Temperature LimitAmbient operating temperature must be held at 65ºC or below to keep class BS detectors clear of unwanted alarm conditions.
- Low Profile ABS HousingThe ABS housing is 102mm in diameter, 40.5mm high (plus 9.5mm for standard base), and weighs 70g (plus 45g for standard base).
- Range Of Detector BasesThe detector can be used with the 2020B, 2020BSD, 2020DB and 2020DBSD bases.
- Remote Laser TriggeringThe 2020LT hand held laser tool triggers the detector remotely but does not negate the requirement to test it as specified in BS 5839 Pt 1:2013.
Description
The 2020HF is the fixed temperature member of the Vision conventional detector range, its heat element working alongside an ASIC and a static element. Its approval is Class BS to EN54 - 5:2000 (Amendment 1), LPCB and CE approval is held, and the class carries a condition: class BS detectors can be triggered into unwanted alarm conditions where ambient operating temperature runs above 65ºC, so that figure is the working ceiling, inside a wider application range of -30ºC to +70ºC.
Electrically the head sits on a 14 to 28VDC line at a maximum standby current of 75μA @ 24VDC and 70mA @ 28VDC in alarm, its terminals rated for 0.4mm2 to 2.0mm2 conductors. It is rated for 5 to 95% Relative Humidity (non-condensing). Its body is a low profile ABS moulding of 102mm diameter finished to approximate RAL9016.
Read the full technical description
A variety of detector bases suit it - the standard 2020B and deep 2020DB, plus 2020BSD and 2020DBSD carrying a Schottky diode - and the 2020LT hand held laser tool triggers the detector remotely, which does not negate the requirement to test the detector as specified in BS 5839 Pt 1:2013.
The 2020HF is a conventional fixed temperature heat detector from the Vision range, set to operate at 78ºC and using a heat element with an ASIC and a static element for quick and accurate detection of fires. Approval is Class BS under EN54 - 5:2000 (Amendment 1), the standard being EN54 Part 5, and the detector is LPCB Approved and CE Approved.
Supply is 14 to 28VDC (Nominal 24VDC). Standby draw is held to a maximum of 75μA @ 24VDC at 25ºC, rising to no more than 70mA @ 28VDC in alarm. An integral LED gives a local alarm signal, latching on until reset by a momentary power interruption; an optional remote LED annunciator may repeat that signal, and a remote alarm trigger feature is provided.
The ABS housing approximates RAL9016, measures 102mm across and stands 40.5mm high, with 9.5mm added by a standard base, and weighs 70g before the 45g of that base. It is specified for -30ºC to +70ºC in 5 to 95% Relative Humidity (non-condensing), though ambient operating temperature must be kept to 65ºC or less, since class BS detectors above that point are liable to unwanted alarm conditions.
Bases come in standard and deep forms: the 2020B adds 9.5mm to detector height and the 2020DB adds 21mm, while the 2020BSD and 2020DBSD carry a Schottky diode. Remote triggering by the 2020LT laser tool does not negate the requirement to test the detector as specified in BS 5839 Pt 1:2013.
Specifications
| Detector type | 78ºC Fixed Temperature Heat Detector |
|---|---|
| Operating voltage range | 14 to 28VDC (Nominal 24VDC) |
| Maximum standby current | Maximum Standby Current @ 25ºC 75μA @ 24VDC |
| Maximum alarm current | Maximum Alarm Current 70mA @ 28VDC |
| Max wire gauge for terminals | 0.4mm2 to 2.0mm2 |
| Application temperature range | -30ºC to +70ºC (see note 1) |
| Max ambient operating temperature note | To avoid unwanted alarm conditions being triggered by class BS detectors the maximum ambient operating temperature should not exceed 65ºC. |
| Humidity | 5 to 95% Relative Humidity (non-condensing) |
|---|---|
| Height | 40.5mm (plus 9.5mm for standard base) |
| Diameter | 102mm |
| Weight | 70g (plus 45g for standard base) |
| Colour | Approximates RAL9016 |
| Material | ABS |
| Standards | EN54 Part 5 |
Specifications per manufacturer documentation, subject to change. E&OE.