Skip to content

Trade prices shown ex VAT. Order by 3pm on a working day for same-day dispatch on stocked lines, UK mainland. Free UK delivery on orders over £250 ex VAT.

Part Number or the Week S3EP-V-VAD-HPR-R

VESDA XCL Flammable 100 %LEL, (4-20mA Relays)

Part no.XCL-LB-CH4-RA
BrandVESDA
RangeGas Detection XCL
VESDA XCL-LB-CH4-RA XCL Methane Detector — black housing with horizontal large-bore tube and red-capped vertical tube

Image for illustration; item supplied may differ

Description

The XCL-LB-CH4-RA is a VESDA Sensepoint XCL Large Bore gas detector for methane (CH4), measuring across a 0-100% LEL range. It delivers a 4-20mA analogue output with relay, integrating directly into combustible-gas monitoring systems on Large Bore aspirated sampling networks.

XCL-LB-CH4-RA pairs methane detection across 0 to 100% LEL with a 4-20mA analogue output and relay, serving as a flammable-gas detector in the Xtralis VESDA Sensepoint XCL Large Bore family. The analogue build ties directly into combustible-gas monitoring systems on Large Bore aspirated sampling networks and carries one wiring particular of its own: a loopback resistor must be connected correctly, since the detector's diagnostics flag an mA output failure (Fault 9) when it is not.

Read the full technical description

Commissioning changes go through the Sensepoint App, which is also the recovery route the troubleshooting guidance names for Fault 4 and Fault 7 conditions.

For upkeep, the XCL-SC-CH4 replacement sensor renews the catalytic flammable sensing element, while companion accessories for a Large Bore installation take in the XCL-LB-CAP flow cap, XCL-M20-CG cable glands and XCL-LB-ELB 60-degree pipe elbows. Physical wiring and connection detail sits in the Large Bore installation manual.

Specifications

Part descriptionVESDA XCL LB CH 4 0-100%LEL 4-20mA REL
Measurement range0-100%LEL
Output type4-20mA
Manual referenceVESDA Sensepoint XCL - Large Bore Installation Manual
WarrantyXtralis warrants the VESDA Sensepoint XCL gas detector against defective parts and workmanship.
Warranty exclusionsDoes not cover consumable, batteries, fuses, normal wear and tear, or damage caused by accident, abuse, improper installation, unauthorized use, modification or repair, ambient environment, poisons, contaminants or abnormal operating conditions. Does not apply to sensors or components covered under separate warranties, or to any 3rd-party cables and components.

Specifications per manufacturer documentation, subject to change. E&OE.

Documents

DocumentTypeSizeDownload
Honeywell XCL LB CO2VV RA Gas Detector ManualOperatingDownload PDF

Optional accessories