VESDA XCL Flammable 100 %LEL, (4-20mA Relays)
| Part no. | XCL-LB-CH4-RA |
|---|---|
| Brand | VESDA |
| Range | Gas Detection XCL |

Image for illustration; item supplied may differ
Description
The XCL-LB-CH4-RA is a VESDA Sensepoint XCL Large Bore gas detector for methane (CH4), measuring across a 0-100% LEL range. It delivers a 4-20mA analogue output with relay, integrating directly into combustible-gas monitoring systems on Large Bore aspirated sampling networks.
XCL-LB-CH4-RA pairs methane detection across 0 to 100% LEL with a 4-20mA analogue output and relay, serving as a flammable-gas detector in the Xtralis VESDA Sensepoint XCL Large Bore family. The analogue build ties directly into combustible-gas monitoring systems on Large Bore aspirated sampling networks and carries one wiring particular of its own: a loopback resistor must be connected correctly, since the detector's diagnostics flag an mA output failure (Fault 9) when it is not.
Read the full technical description
Commissioning changes go through the Sensepoint App, which is also the recovery route the troubleshooting guidance names for Fault 4 and Fault 7 conditions.
For upkeep, the XCL-SC-CH4 replacement sensor renews the catalytic flammable sensing element, while companion accessories for a Large Bore installation take in the XCL-LB-CAP flow cap, XCL-M20-CG cable glands and XCL-LB-ELB 60-degree pipe elbows. Physical wiring and connection detail sits in the Large Bore installation manual.
Specifications
| Part description | VESDA XCL LB CH 4 0-100%LEL 4-20mA REL |
|---|---|
| Measurement range | 0-100%LEL |
| Output type | 4-20mA |
| Manual reference | VESDA Sensepoint XCL - Large Bore Installation Manual |
| Warranty | Xtralis warrants the VESDA Sensepoint XCL gas detector against defective parts and workmanship. |
| Warranty exclusions | Does not cover consumable, batteries, fuses, normal wear and tear, or damage caused by accident, abuse, improper installation, unauthorized use, modification or repair, ambient environment, poisons, contaminants or abnormal operating conditions. Does not apply to sensors or components covered under separate warranties, or to any 3rd-party cables and components. |
Specifications per manufacturer documentation, subject to change. E&OE.
Documents
| Document | Type | Size | Download |
|---|---|---|---|
| Honeywell XCL LB CO2VV RA Gas Detector Manual | Operating | Download PDF |
Optional accessories
- XCL-LB-CAPXCL Spare Flow CapAccessory XCL-LB-CAP (VESDA XCL LB SP FLOW CAP) listed in the same Large Bore ordering/acc£98.90ex VAT£118.68 inc VATIn stock
- XCL-M20-CGVESDA Sensepoint XCL Cable Glands - Pack of 10Accessory XCL-M20-CG (VESDA XCL SP CBL GLNDS PK 10) listed in the accessories section.£75.90ex VAT£91.08 inc VATIn stock
- XCL-LB-ELBXCL Large Bore 60° Pipe ElbowAccessory XCL-LB-ELB (VESDA XCL LB SP 60DEG ELB PK 4) listed in the accessories section.£94.88ex VAT£113.86 inc VATIn stock
Spares & replacement parts
- XCL-SC-CH4XCL Sensor-Flam CatalyticReplacement gas sensor for the flammable (CAT) variant£330.63ex VAT£396.76 inc VATIn stock