Retro-fit MRC Kit VSRPT-MRC (Mark 4) · Gent Legacy
Gent VSRPT-MRC Retrofit Master Repeat Card Mark-4 Kit
- Product type
- Retro-fit MRC Kit VSRPT-MRC (Mark 4)
- Kit contents
- Spacer, Qty 5
- Mains fuse
- FS4 3.15A(T) mains fuse
- Fuse
- FS3 2A(QB)
- Rotary switch
- Rotary switch SW3 (with settings table); located below the 40-way ribbon cable header P2 on the new Master Repeat Card
- Rotary switch setting
- 0 = A2/A3/A4 Mimic Panel only
Overview
What it is and how it fits the system.
The Gent VSRPT-MRC is the Retrofit Master Repeat Card (MRC) Mark-4 kit, designed for loop-wired old Repeat and A2 Mimic panels installed in EN54 or BS5839 Gent analogue and addressable fire detection and alarm systems. The kit ships complete with a Mark 4 card and protective cover, 2A and 3A15 fuses, 20-way adaptor and ribbon cables, a 40-way ribbon cable, and the M4 screw, washers and spacers needed for installation.
Technical overview
VSRPT-MRC is the Gent Retro-fit MRC Kit (Mark 4), a replacement Master Repeat Card package for loop wired old Repeat panels and A2 Mimic panels installed in EN54 / BS5839 Gent analogue and addressable fire detection and alarm systems. The kit supersedes the VIG-BS-RPT-UPGR, VIG-EN-RPT-UPGR and VSRPT-MRC-V3+ upgrade parts.
Rotary switch SW3 on the new Master Repeat Card selects the legacy host: the A2/A3/A4 Mimic Panel, the 3400 Repeat panel (4 line display), the 32000 Repeat panel (16 line display), or Vigilon Repeat panels with 16 line or 8 line displays. Compatibility requires system control panels having a Loop Processor Card, New Shorter Card only, at version V4.19 / 3.90 or greater. Communication is over an RS485 interface, with L and N mains supply terminals protected by an FS4 3.15A(T) mains fuse; a second fuse position, FS3, is rated 2A(QB), and a write-protect option is factory-set to Write Protected.
SW3 is positioned on the new card just below the header for the 40-way ribbon cable (P2). During fitting, the terminal card ribbon cable connects to socket P16 on the Retrofit MRC, the battery lead to socket P5 and the spade end of the earth lead to P17; step-by-step fitting is detailed in the installation leaflet.
Specifications
Full technical data for this part.
| Product type | Retro-fit MRC Kit VSRPT-MRC (Mark 4) |
|---|---|
| Kit contents | Spacer, Qty 5 |
| Mains fuse | FS4 3.15A(T) mains fuse |
| Fuse | FS3 2A(QB) |
| Rotary switch | Rotary switch SW3 (with settings table); located below the 40-way ribbon cable header P2 on the new Master Repeat Card |
| Rotary switch setting | 0 = A2/A3/A4 Mimic Panel only |
Specifications sourced from manufacturer documentation.