Part Number or the Week S3EP-V-VAD-HPR-R

Gent Replacement Card for Mains Powered Interface (34440)

Part no.VSINTM-PCB-UPG
BrandGent
RangeGent Legacy
Sub-rangeInterface Module Spares
Gent VSINTM-PCB-UPG Replacement Card for Mains Powered Interface — green PCB with terminal blocks and grey power module

Image for illustration; item supplied may differ

At a glance

  • For the legacy 34440 interfaceReplacement mains interface board mounted on a carrier for the existing enclosure.
  • Four configurable channelsSupplied as four sector outputs, with zone inputs and sector outputs configured using S4-INTERFACE-PROG version 1.03 or later.
  • Combined output limit of 0.5ASector and auxiliary output loads share a maximum total of 0.5A.
  • Auxiliary equipment supplyThe auxiliary output supplies up to 0.25A within the combined output limit.
  • Zone and sector end-of-line componentsNon-IS zone circuits use a 22uF end-of-line capacitor; sector circuits use a 10k ohm end-of-line resistor.
  • Carrier fixing and earthingThe supplied fixing screws secure the carrier and form part of the earth path to the metal enclosure.

Description

The Gent VSINTM-PCB-UPG is a replacement mains interface board on a carrier for an existing Gent 34440 mains powered interface. It has four channels, set at the factory as sector outputs, which can be set as zone inputs or sector outputs to suit the site’s required functions. The old board, transformer, mains filter and terminal blocks are removed as part of the conversion. The new board fits into the existing enclosure, with its fixing screws forming part of the earth path. Its sector and auxiliary outputs share a total load limit of 0.5A, with up to 0.25A available from the auxiliary output.

The VSINTM-PCB-UPG replaces the board in a legacy Gent 34440 mains powered interface. The replacement assembly is mounted on a carrier that fits into the existing enclosure. Conversion removes the original board, mains terminal block, mains filter, transformer terminal block and transformer. The incoming mains cable enters above the replacement board’s mains terminal block to keep mains and extra low voltage wiring apart. Unused cable entries need plastic bungs.

Read the full technical description

The VSINTM-PCB-UPG replaces the board in a legacy Gent 34440 mains powered interface. The replacement assembly is mounted on a carrier that fits into the existing enclosure. Conversion removes the original board, mains terminal block, mains filter, transformer terminal block and transformer. The incoming mains cable enters above the replacement board’s mains terminal block to keep mains and extra low voltage wiring apart. Unused cable entries need plastic bungs.

All four channels are supplied set as sector outputs. Use S4-INTERFACE-PROG version 1.03 or later to set the zone inputs and sector outputs needed for the installation. Configure the circuits before connecting external equipment. Channel blocks PB2 to PB5 provide separate sector and zone terminals; PB1 carries the loop connections and PB6 the auxiliary output.

The combined load on the sector outputs and auxiliary output must stay within 0.5A. The auxiliary output has its own 0.25A maximum within that total. Sector circuits use a 10k ohm end-of-line resistor, while non-IS zone circuits use a 22uF end-of-line capacitor. The maximum cable length is 150m for either circuit. An inductive sector load needs a flyback diode.

Stop the loop at the control panel, isolate the mains supply and disconnect the batteries before removing the old board. Secure the replacement carrier with the supplied screws to maintain the earth path to the metal enclosure. After reconnection and power-up, allocate the loop from the control panel and test the interface against the site’s required functions.

Specifications

BrandGent
ApplicationLegacy 34440 mains powered interface
AssemblyReplacement board mounted on a carrier
Power sourceMains supply with battery connection
Channels4, factory set as sector outputs
Channel configurationZone inputs and sector outputs
Configuration toolS4-INTERFACE-PROG version 1.03 or later
Combined output load0.5A maximum across sectors and auxiliary output
Auxiliary output load0.25A maximum, included in the 0.5A combined total
Sector end-of-line component10k ohm resistor
Non-IS zone end-of-line component22uF capacitor
Zone and sector cable length150m maximum
MountingCarrier fixed into the existing enclosure with supplied screws
Earth continuityCarrier fixing screws form part of the earth path to the metal enclosure

Specifications per manufacturer documentation, subject to change. E&OE.

Documents

DocumentTypeSizeDownload
Installation manual (VSINTM-PCB-UPG, W1A-R470SG-K013-81)Installation163 KBDownload PDF

Optional accessories

FAQs

What does the VSINTM-PCB-UPG replace?

It replaces the mains interface board in a legacy Gent 34440 interface. The new board is mounted on a carrier and fits into the existing enclosure. The conversion also removes the original transformer, mains filter, mains terminal block and transformer terminal block. Incoming mains wiring is rerouted above the new board’s mains terminal block, with mains and extra low voltage cables kept apart. The carrier fixing screws form part of the earth connection to the enclosure.

How are the four channels configured?

All four channels leave the factory set as sector outputs. S4-INTERFACE-PROG version 1.03 or later sets the zone inputs and sector outputs needed to reproduce the installation’s channel arrangement. Configuration takes place before external circuits are connected. Each channel has separate sector and zone terminals on blocks PB2 to PB5. Sector circuits use a 10k ohm end-of-line resistor, while non-IS zone circuits use a 22uF capacitor. Both circuit types have a maximum cable length of 150m.

How much current is available for external equipment?

The sector outputs and auxiliary output share a maximum combined load of 0.5A. The auxiliary output is limited to 0.25A, and its load counts towards that combined total. For example, using the full 0.25A auxiliary allowance leaves up to 0.25A for the sector outputs together. The auxiliary connections are on PB6, with the sector connections on PB2 to PB5. An inductive load connected to a sector output needs a flyback diode across the load.

What installation work does the conversion involve?

The loop is stopped at the main control panel, and the interface’s mains and battery supplies are isolated before the original board is removed. The old transformer, mains filter and associated terminal blocks also come out. The replacement carrier is secured using the supplied screws, which maintain the earth path to the metal enclosure. The mains cable enters above the new mains terminal block, and unused cable entries are closed with plastic bungs to complete the enclosure work.

What happens after the replacement board is fitted?

The external wiring is reconnected to the replacement board after its inputs and outputs have been configured. The correct end-of-line components need to be in place for the zone and sector circuits. Once the mains and battery connections are restored, the loop is allocated again from the control panel’s Test/Eng menu. The interface is then tested against the functions required at the site. The enclosure door is closed and secured with its key after the work is complete.