Gent Battery Box for VIGPLUS-72 & VIGPLUS-72-NP. Batteries not included - 72hr panels require 4 x 4015-602-YFR (Power Sonic Flame Retardant 12V 21Ah) to meet compliance regulations.
| Part no. | VS-BATTBOX-72 |
|---|---|
| Brand | Gent |
| Range | Vigilon Plus |
| Sub-range | Vigilon Plus Accessories |

Image for illustration; item supplied may differ
At a glance
- VIGPLUS-72Fits VIGPLUS-72 panels.
- VIGPLUS-72-NPFits VIGPLUS-72-NP panels.
- External battery enclosureHouses the batteries outside the control panel.
- Separate batteriesBatteries are supplied separately; a pair of 550 door keys, battery wiring harnesses, a terminal block and four fuses are included.
- Four batteries requiredThe 72-hour panel requires four 4015-602-YFR batteries.
- Battery typePower Sonic flame retardant 12V 21Ah batteries.
Description
The Gent VS-BATTBOX-72 is an external battery box for VIGPLUS-72 and VIGPLUS-72-NP fire alarm panels, also used for the VIG72-UPGR Plus conversion. Supplied with a pair of 550 door keys, battery wiring harnesses, a terminal block and four fuses. Four 4015-602-YFR Power Sonic flame retardant 12V 21Ah batteries are required and supplied separately. The box has upper and lower shelves and a lockable door. It can sit beneath the panel or remotely, up to 10m away with 1.5mm² MICC or 15m with 2.5mm² MICC. An earth lead connects the panel and box.
VS-BATTBOX-72 is an external battery enclosure for VIGPLUS-72 and VIGPLUS-72-NP panels. The battery requirement for the 72-hour panel is four 4015-602-YFR Power Sonic flame retardant 12V 21Ah batteries, supplied separately.
Read the full technical description
VS-BATTBOX-72 is an external battery enclosure for VIGPLUS-72 and VIGPLUS-72-NP panels. The battery requirement for the 72-hour panel is four 4015-602-YFR Power Sonic flame retardant 12V 21Ah batteries, supplied separately.
In a Vigilon Plus installation, the battery box may occupy a position below the panel or be installed remotely. The maximum panel-to-box cable distance is 10m with 1.5mm² MICC or 15m with 2.5mm² MICC.
The Plus battery box has upper and lower shelves and a lockable door. Supplied with a pair of 550 door keys, battery wiring harnesses, a terminal block and four fuses. An earth lead is required between the panel and battery box.
VS-BATTBOX-72 is also used for the VIG72-UPGR Plus conversion.
Specifications
| Manufacturer | Gent |
|---|---|
| Product type | External panel battery enclosure |
| Panel fit | VIGPLUS-72; VIGPLUS-72-NP |
| Supplied with | A pair of 550 door keys, battery wiring harnesses, one terminal block and four fuses; batteries supplied separately |
| Current battery order | 4 x 4015-602-YFR |
| Specified battery | Power Sonic flame retardant 12V 21Ah |
| Plus installation: box positions | Beneath the control panel or remote |
| Plus installation: 1.5mm² MICC | 10m maximum panel-to-box cable distance |
| Plus installation: 2.5mm² MICC | 15m maximum panel-to-box cable distance |
| Plus installation: earth continuity | Earth lead between control panel and battery box |
Specifications per manufacturer documentation, subject to change. E&OE.
Documents
| Document | Type | Size | Download |
|---|---|---|---|
| Installation manual (VS-BATTBOX, VS-BATTBOX-72) | Installation | 164 KB | Download PDF |
| Installation manual (VS-BATTBOX, VS-BATTBOX-72, VS-FILTER-72) | Installation | 216 KB | Download PDF |
FAQs
Which panels does VS-BATTBOX-72 fit?
VS-BATTBOX-72 is the external battery enclosure for VIGPLUS-72 and VIGPLUS-72-NP fire alarm panels. It is also used for the VIG72-UPGR Plus conversion. Four 4015-602-YFR Power Sonic flame retardant 12V 21Ah batteries are required for the 72-hour panel and are supplied separately. In a Plus installation, the battery box may occupy a position below the control panel or be installed remotely. An earth lead is required between the panel and the battery box.
Does VS-BATTBOX-72 include batteries?
The batteries are supplied separately from the box. The 72-hour panel requires four 4015-602-YFR Power Sonic flame retardant 12V 21Ah batteries. The box comes with a pair of 550 door keys, battery wiring harnesses, a terminal block and four fuses. VS-BATTBOX-72 houses the batteries outside the VIGPLUS-72 or VIGPLUS-72-NP control panel. It has upper and lower shelves and a lockable door, and can be fitted beneath the panel or at a remote location.
Can the battery box be installed away from the panel?
Yes. In a Vigilon Plus installation, the battery box may occupy a position below the control panel or be installed remotely. The maximum cable distance between the panel and box is 10m with 1.5mm² MICC or 15m with 2.5mm² MICC. An earth lead is required between the two enclosures. VS-BATTBOX-72 is the external panel battery box for VIGPLUS-72 and VIGPLUS-72-NP panels and is also used for the VIG72-UPGR Plus conversion.
What is the internal arrangement of the Plus battery box?
The Plus battery box has an upper shelf and a lower shelf, with a lockable door. An earth lead is required between the control panel and the box. The box can be fitted beneath the panel or at a remote location. For the VIGPLUS-72 and VIGPLUS-72-NP panels, the battery requirement is four 4015-602-YFR Power Sonic flame retardant 12V 21Ah batteries, supplied separately. The maximum remote cable distance is 10m with 1.5mm² MICC or 15m with 2.5mm² MICC.
Is this box used for a VIG72-UPGR Plus conversion?
Yes. VS-BATTBOX-72 is the external battery enclosure for the VIG72-UPGR Plus conversion. Four 4015-602-YFR Power Sonic flame retardant 12V 21Ah batteries are supplied separately. The Plus battery box can sit beneath the panel or at a remote location. The maximum panel-to-box cable distance is 10m with 1.5mm² MICC or 15m with 2.5mm² MICC, and an earth lead is required between the enclosures. The box has upper and lower shelves and a lockable door.
Also in this range
- VS-BATTBOXBattery Box for Vigilon Panel (excludes batteries)£771.08ex VAT£925.30 inc VATIn stock