Gent Legacy

Gent Vigilon VIG-BSKIT-NODE EN to BS Node Conversion Kit

Kit contents
1 x Blank label
Loop processor card
1 x Loop Processor Card (LPC) (BS - version 3) (Not supplied with VIG-BSKIT-NODE)
Loop support note
The Loop Processor Card is supplied with the conversion kit VIG-BSKIT but not with the kit VIG-BSKIT-NODE, as the Network node does not support Loop circuits.
Loop processor applicability
Note: The loop processor cards are not applicable for Network node.
Mcc fitting location
Master Controller Card (MCC) to be fitted to socket P1 CARD 0 on backplane
Ribbon cables
20-way and 40-way ribbon cables (re-connected to the replacement MCC and secured in the clamp on the backplane)
Document reference
4188-913.01_04/07_EN to BS kits

Overview

What it is and how it fits the system.

The VIG-BSKIT-NODE is an EN-to-BS conversion kit installed in a VIG-NODE-24 to convert it from an EN network node to a BS network node. It is supplied with one BS version 3 Main Control Card (MCC), a commission/warning LED label and a blank label; loop processor cards are not applicable for a network node. The MCC fits to socket P1 Card 0 on the backplane and reconnects via the 20-way and 40-way ribbon cables. Reference 4188-913.01.

Technical overview

VIG-BSKIT-NODE is an EN-to-BS conversion kit from Gent by Honeywell, part of the Gent Legacy V3+ range, designed to convert a VIG-NODE-24 from an EN Network node to a BS Network node. It comprises a BS version 3 Main Control Card (MCC) together with a commission/warning LED label and a blank label. Loop processor cards are not applicable to a Network node, which does not support loop circuits.

The MCC fits into socket P1 Card 0 on the backplane and reconnects through the 20-way and 40-way ribbon cables, with the physical wiring covered in the installation manual. The commission/warning label is placed on the control and indication membrane over the Disablement, Test and Delay LEDs to suit a BS compliant system, while the blank label covers the Sounder LED, whose indication does not apply under BS. Documentation reference 4188-913.01 provides further guidance on the conversion process.

Specifications

Full technical data for this part.

Kit contents1 x Blank label
Loop processor card1 x Loop Processor Card (LPC) (BS - version 3) (Not supplied with VIG-BSKIT-NODE)
Loop support noteThe Loop Processor Card is supplied with the conversion kit VIG-BSKIT but not with the kit VIG-BSKIT-NODE, as the Network node does not support Loop circuits.
Loop processor applicabilityNote: The loop processor cards are not applicable for Network node.
Mcc fitting locationMaster Controller Card (MCC) to be fitted to socket P1 CARD 0 on backplane
Ribbon cables20-way and 40-way ribbon cables (re-connected to the replacement MCC and secured in the clamp on the backplane)
Document reference4188-913.01_04/07_EN to BS kits
DisposalWEEE Directive: At the end of their useful life, the packaging, product and batteries should be disposed of via a suitable recycling centre.
Disposal warningDo not dispose of with your normal household waste. Do not burn.

Specifications sourced from manufacturer documentation.

Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know