Gent Vigilon VIG-BSKIT-NODE EN to BS Node Conversion Kit
- Kit contents
- 1 x Blank label
- Loop processor card
- 1 x Loop Processor Card (LPC) (BS - version 3) (Not supplied with VIG-BSKIT-NODE)
- Loop support note
- The Loop Processor Card is supplied with the conversion kit VIG-BSKIT but not with the kit VIG-BSKIT-NODE, as the Network node does not support Loop circuits.
- Loop processor applicability
- Note: The loop processor cards are not applicable for Network node.
- Mcc fitting location
- Master Controller Card (MCC) to be fitted to socket P1 CARD 0 on backplane
- Ribbon cables
- 20-way and 40-way ribbon cables (re-connected to the replacement MCC and secured in the clamp on the backplane)
- Document reference
- 4188-913.01_04/07_EN to BS kits
Overview
What it is and how it fits the system.
The VIG-BSKIT-NODE is an EN-to-BS conversion kit installed in a VIG-NODE-24 to convert it from an EN network node to a BS network node. It is supplied with one BS version 3 Main Control Card (MCC), a commission/warning LED label and a blank label; loop processor cards are not applicable for a network node. The MCC fits to socket P1 Card 0 on the backplane and reconnects via the 20-way and 40-way ribbon cables. Reference 4188-913.01.
Technical overview
VIG-BSKIT-NODE is an EN-to-BS conversion kit from Gent by Honeywell, part of the Gent Legacy V3+ range, designed to convert a VIG-NODE-24 from an EN Network node to a BS Network node. It comprises a BS version 3 Main Control Card (MCC) together with a commission/warning LED label and a blank label. Loop processor cards are not applicable to a Network node, which does not support loop circuits.
The MCC fits into socket P1 Card 0 on the backplane and reconnects through the 20-way and 40-way ribbon cables, with the physical wiring covered in the installation manual. The commission/warning label is placed on the control and indication membrane over the Disablement, Test and Delay LEDs to suit a BS compliant system, while the blank label covers the Sounder LED, whose indication does not apply under BS. Documentation reference 4188-913.01 provides further guidance on the conversion process.
Specifications
Full technical data for this part.
| Kit contents | 1 x Blank label |
|---|---|
| Loop processor card | 1 x Loop Processor Card (LPC) (BS - version 3) (Not supplied with VIG-BSKIT-NODE) |
| Loop support note | The Loop Processor Card is supplied with the conversion kit VIG-BSKIT but not with the kit VIG-BSKIT-NODE, as the Network node does not support Loop circuits. |
| Loop processor applicability | Note: The loop processor cards are not applicable for Network node. |
| Mcc fitting location | Master Controller Card (MCC) to be fitted to socket P1 CARD 0 on backplane |
| Ribbon cables | 20-way and 40-way ribbon cables (re-connected to the replacement MCC and secured in the clamp on the backplane) |
| Document reference | 4188-913.01_04/07_EN to BS kits |
| Disposal | WEEE Directive: At the end of their useful life, the packaging, product and batteries should be disposed of via a suitable recycling centre. |
| Disposal warning | Do not dispose of with your normal household waste. Do not burn. |
Specifications sourced from manufacturer documentation.
Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know