VESDA Modbus MK1 HLI

Part no.VHX-0400
BrandVESDA
RangeVESDA Programming and Connectivity
VESDA VHX-0400 ModBus HLI Type 1 Interface — grey rectangular housing with side vents and front port

Image for illustration; item supplied may differ

At a glance

  • ModBus HLI Type 1VHX-0400 is the ModBus HLI - Type 1 of the VESDA ModBus HLI range.
  • RS232 Character EchoIt echoes each character received on the RS232 link back to the host together with reply message.
  • Forty Detector MaximumOne ModBus HLI is used to interface to a VESDAnet, up to a maximum of 40 VESDA detectors.
  • Zone Number RangeIt works with VESDAnet detector zone numbers between 1 to 200.
  • Seven Logical NetworksThe Modbus HLI divides the address range into 7 logical networks, so the first 30 addresses are considered in network 1 and addresses between 31 to 60 are in network 2.
  • Detector Type ReportingDetector Type (VLP, VLS, VLC, VLF) is reported to the host.

Description

Echoing is what defines the Type 1 unit: every character arriving on the RS232 link is returned to the host along with the reply message.

A single unit serves one VESDAnet, carrying as many as 40 VESDA detectors, with the address range split into 7 logical networks. Detector Type reporting covers VLP, VLS, VLC and VLF. Secondary monitoring is the role recommended for this interface - fire alarms, together with the other notifications a VESDAnet passes on. The interface is also suitable for primary reporting, once integrated and approved or listed jointly with whichever fire panel or other primary reporting system receives the report, under the fire standards and codes in force.

Read the full technical description

VHX-0400 is the ModBus HLI - Type 1 of the Xtralis VESDA ModBus HLI range, an interface between a VESDAnet and any PC monitoring tool, BMS or FACP that supports the ModBus protocol. Type 1 echoes each character received on the RS232 link back to the host together with reply message.

One ModBus HLI is used to interface to a VESDAnet, up to a maximum of 40 VESDA detectors, and it works with VESDAnet detector zone numbers between 1 to 200. The Modbus HLI divides the address range into 7 logical networks, so the first 30 addresses are considered in network 1, addresses between 31 to 60 are in network 2 and so on.

Detector Type (VLP, VLS, VLC, VLF) is reported to the host. By recommendation a VESDA HLI does secondary monitoring work, though primary reporting is also suitable; put to that duty it must first be integrated and approved or listed together with the fire panel or reporting system it feeds, against the applicable fire standards and codes.

Specifications

TypeModBus HLI - Type 1
Echo functionEchoes each character received on the RS232 link back to the host together with reply message
Supply voltage24 VDC
Current consumption70 mA (Quiescent)
Power consumption1.68 W (Quiescent)
Dimensions188 mm x 98 mm x 40 mm (7.4 in. x 3.9 in. x 1.6 in. approx.)
Weight0.4 kg (0.9 lbs)
Number of detectors supportedUp to 200 VESDA Devices (includes max 40 detectors and remaining VESDA ancillary devices)
Max detectors per vesdanetModbus HLI supports up to a maximum of 40 VESDA detectors on a VESDAnet
Zone number rangesupports VESDAnet detector zone numbers between 1 to 200, divided into 7 logical networks
Modem supportModem support is not available
Supplied withVESDAlink RS-232 9-way serial cable (male-female). VESDAnet RS-485 15-way cable (male-female)
Product warranty2 years
Host interfaceRS-232 / RS-485

Specifications per manufacturer documentation, subject to change. E&OE.