- Zones
- 200 (max)
- Loop capacity
- ZX5Se Loop Capacity: 1 to 5 loops 460mA per loop maximum
- Zonal indicators
- LED TYPE ZONAL INDICATORS FIRE/FAULT/TEXT/DISABLED: 20 (Up to 200 available on special request)
- Internal sounder
- Yes
- User controls
- Sound Alarms, Silence/Resound, Mute Buzzer, Accept, System Reset
- Programming controls
- Alphanumeric multi-level keypad
- General panel status indicators
- FIRE, FAULT, Acknowledged, Disablement, Test, Sounder Fault, Delayed Mode, Relays Disabled, Earth Fault, System/CPU Fault, Sounders Disabled, Alarms Silenced, Supply Fault, Power
You will also need
Needed to install, power or certify this product.
722-001-301
Morley Addressable PanelsFire Panel722-001-301
ZX1Se single loop control panel. 230Vac, 2 sounder circuits, 4 line display and networking capability. 400 x 400 x 135mm (H x W x D). Order loop cards separately. Languages supplied: English, Italian, Spanish, Portuguese, Polish, Dutch, Slovenian and Croatian. Supplied with 20 zonal LED's , not expandable
Separate battery box for the ZX1Se panel
£1,081.18
ex VAT
£1,297.42 inc VAT
Sold separately
720-001-301
Morley Addressable PanelsFire Panel720-001-301
ZX2Se 1-2 loop control panel. 230Vac, 2 sounder circuits, 4 line display and networking capability. 400 x 400 x 135mm (H x W x D). Order loop cards separately. Languages supplied: English, Italian, Spanish, Portuguese, Polish, Dutch, Slovenian and Croatian. Supplied with 20 zonal LED's , not expandable
Separate battery box for the ZX2Se panel
£1,446.57
ex VAT
£1,735.88 inc VAT
Sold separately
Specifications
Full technical data for this part.
| Zones | 200 (max) |
|---|---|
| Loop capacity | ZX5Se Loop Capacity: 1 to 5 loops 460mA per loop maximum |
| Zonal indicators | LED TYPE ZONAL INDICATORS FIRE/FAULT/TEXT/DISABLED: 20 (Up to 200 available on special request) |
| Internal sounder | Yes |
| User controls | Sound Alarms, Silence/Resound, Mute Buzzer, Accept, System Reset |
| Programming controls | Alphanumeric multi-level keypad |
| General panel status indicators | FIRE, FAULT, Acknowledged, Disablement, Test, Sounder Fault, Delayed Mode, Relays Disabled, Earth Fault, System/CPU Fault, Sounders Disabled, Alarms Silenced, Supply Fault, Power |
| Serial interface | 3 serial ports with connections for optional RS485 or RS232 plug-in communication cards |
| Auxiliary relays | EN54 format at 1 fault relay and 1 programmable relay voltage free, changeover outputs contacts rated at 24V AC/DC, 1A, 0.6 pF maximum |
| Sounder outputs | 4 Programmable outputs. Open and short circuit monitoring. 1A maximum per output (Maximum total load 1.3A) |
Specifications sourced from manufacturer documentation.