Morley-IAS ZX1(S)e & 2(S)e Battery box or mounting enclosure. Size 400 x 400 x 135mm (H x W x D)

Part no.797-077
BrandMorley-IAS
RangeMorley ZXSe Panels
Sub-rangeFire Panel Accessories
Morley-IAS 797-077 Battery Box or Mounting Enclosure — white box with key lock, hinges and top vents

Image for illustration; item supplied may differ

At a glance

  • Battery Box or Mounting EnclosureServes as a battery box or a mounting enclosure for ZX1(S)e and ZX2(S)e panels.
  • ZX1(S)e and ZX2(S)e CompatibleSupplied for the Morley-IAS ZX1(S)e and ZX2(S)e control panels.
  • 400 x 400 x 135mmThe enclosure measures 400 x 400 x 135mm (H x W x D).
  • Fire Panel AccessoryA Morley ZXSe range fire panel accessory. It is not a control panel.

Description

The 797-077 is the battery box or mounting enclosure supplied for Morley-IAS ZX1(S)e and ZX2(S)e fire alarm control panels. Its dimensions are 400 x 400 x 135mm (H x W x D).

It is a fire panel accessory in the Morley ZXSe range. It carries no control electronics and is not a fire alarm control panel.

Read the full technical description

The 797-077 is the battery box or mounting enclosure for the Morley-IAS ZX1(S)e and ZX2(S)e control panels. It measures 400 x 400 x 135mm (H x W x D).

It is an enclosure, not a control panel. It houses batteries or provides a mounting position alongside an installed ZX1(S)e or ZX2(S)e panel.

Specifications

Zones200 (max)
Loop capacityZX5Se Loop Capacity: 1 to 5 loops 460mA per loop maximum
Zonal indicatorsLED TYPE ZONAL INDICATORS FIRE/FAULT/TEXT/DISABLED: 20 (Up to 200 available on special request)
Internal sounderYes
User controlsSound Alarms, Silence/Resound, Mute Buzzer, Accept, System Reset
Programming controlsAlphanumeric multi-level keypad
General panel status indicatorsFIRE, FAULT, Acknowledged, Disablement, Test, Sounder Fault, Delayed Mode, Relays Disabled, Earth Fault, System/CPU Fault, Sounders Disabled, Alarms Silenced, Supply Fault, Power
Serial interface3 serial ports with connections for optional RS485 or RS232 plug-in communication cards
Auxiliary relaysEN54 format at 1 fault relay and 1 programmable relay voltage free, changeover outputs contacts rated at 24V AC/DC, 1A, 0.6 pF maximum
Sounder outputs4 Programmable outputs. Open and short circuit monitoring. 1A maximum per output (Maximum total load 1.3A)

Specifications per manufacturer documentation, subject to change. E&OE.