Morley ZXSe Panels
Morley ZX5Se Addressable Fire Panel 797-063 (5-Loop)
- Loop capacity
- ZX5Se Loop Capacity: 1 to 5 loops 460mA per loop maximum
- Zones
- 200 (max)
- Zonal indicators
- 20 (Up to 200 available on special request)
- Internal sounder
- Yes
- General panel status indicators
- FIRE, FAULT, Acknowledged, Disablement, Test, Sounder Fault, Delayed Mode, Relays Disabled, Earth Fault, System/ CPU Fault, Sounders Disabled, Alarms Silenced, Supply Fault, Power
- Serial interface
- 3 serial ports with connections for optional RS485 or RS232 plug-in communication cards
- Auxiliary relays
- EN54 format at 1 fault relay and 1 programmable relay voltage free, changeover outputs contacts rated at 24V AC/DC, 1A, 0.6 pF maximum
Overview
What it is and how it fits the system.
The Morley 797-063 is a ZX5Se intelligent fire alarm control panel from the Morley-IAS ZXSe range, supporting one to five loops at 460mA per loop and up to 200 zones. It carries 20 LED zonal indicators (expandable to 200 on special request), an internal sounder and four programmable sounder outputs with open and short-circuit monitoring. EN54-format relays and three serial ports enable flexible system integration.
Technical overview
797-063 is the part number assigned to the ZX5Se Fire Alarm Control Panel within the Morley-IAS ZXSE range, a multi-loop platform built out to anywhere between one and five loops, each loop budgeted at 460 mA, with capacity for as many as 200 zones.
Output provision centres on four programmable sounder outputs, monitored for open and short circuit and dimensioned at 1 A each within a 1.3 A total, while the auxiliary relays are arranged to EN54 format, pairing a dedicated fault relay with a programmable relay on voltage-free changeover contacts rated at 24V AC/DC. Three serial ports give the panel its route to optional plug-in communication cards of RS485 or RS232 type.
Indication runs to twenty zonal indicators in the standard build — up to 200 are available on special request — plus an internal sounder, and general status coverage stretches from FIRE and FAULT through disablement, test and delayed mode to earth, supply and system or CPU fault conditions. The installation manual carries the physical wiring and terminal connection detail.
Specifications
Full technical data for this part.
| Loop capacity | ZX5Se Loop Capacity: 1 to 5 loops 460mA per loop maximum |
|---|---|
| Zones | 200 (max) |
| Zonal indicators | 20 (Up to 200 available on special request) |
| Internal sounder | Yes |
| General panel status indicators | FIRE, FAULT, Acknowledged, Disablement, Test, Sounder Fault, Delayed Mode, Relays Disabled, Earth Fault, System/ CPU Fault, Sounders Disabled, Alarms Silenced, Supply Fault, Power |
| Serial interface | 3 serial ports with connections for optional RS485 or RS232 plug-in communication cards |
| Auxiliary relays | EN54 format at 1 fault relay and 1 programmable relay voltage free, changeover outputs contacts rated at 24V AC/DC, 1A, 0.6 pF maximum |
| Sounder outputs | 4 Programmable outputs. Open and short circuit monitoring. 1A maximum per output (Maximum total load 1.3A) |
Specifications sourced from manufacturer documentation.
Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know
Optional accessories
Optional additions — this product works without them.
ZX1Se single loop control panel. 230Vac, 2 sounder circuits, 4 line display and networking capability. 400 x 400 x 135mm (H x W x D). Order loop cards separately. Languages supplied: English, Italian, Spanish, Portuguese, Polish, Dutch, Slovenian and Croatian. Supplied with 20 zonal LED's , not expandable
Glass door kit for the ZX1Se panel
ZX2Se 1-2 loop control panel. 230Vac, 2 sounder circuits, 4 line display and networking capability. 400 x 400 x 135mm (H x W x D). Order loop cards separately. Languages supplied: English, Italian, Spanish, Portuguese, Polish, Dutch, Slovenian and Croatian. Supplied with 20 zonal LED's , not expandable
Glass door kit for the ZX2Se panel