VESDA H2 1000PPM 4-20mA REL XCL VEA Pack of 5
| Part no. | XCL-VEA-H2-RA-5 |
|---|---|
| Brand | VESDA |
| Range | Gas Detection XCL |
Image for illustration; item supplied may differ
Description
The XCL-VEA-H2-RA-5 is a pack of five VESDA Sensepoint XCL aspirated hydrogen (H2) gas detectors for the VESDA-E VEA micro bore network, each with a 1000ppm range and 4-20mA plus relay output. The charcoal polycarbonate units are rated IP65 (Type 4 / NEMA 250) and measure 113 x 113 x 59 mm at 500 g each.
XCL-VEA-H2-RA-5 is the five-detector ordering code for the Xtralis VESDA Sensepoint XCL aspirated hydrogen gas detector in 4-20 mA relay form, each unit covering hydrogen at 1000 ppm on a VESDA-E VEA micro bore tube network. Every detector in the pack inserts in-line, connecting to micro bore tube of 6 mm (1/4 in) OD through flexible tubes.
Read the full technical description
Interfaces are common across the five: integration with fire alarm control panels, PLCs, HVAC and building management systems, configurable relays, VSC and VSM4 remote detector access, and Bluetooth 4.0 (Bluetooth Low Energy) configuration from a compatible smart device running iOS 10 or Android 4.3 or above. Approvals span electrical safety (Conforms to EN/UL/IEC61010-1; Certified to CSA-C22.2 No. 61010-1-12), EMC (CE - EMC; EN 50270) and radio (RED, FCC, BT SIG).
Sensor exchange on any of the detectors uses the XCL-XRL-SC-H2 replacement hydrogen sensor, and the accessory range spans the XCL-FILTER replacement filter, XCL-VEA-CAL calibration/flow cap, XCL-M20-CG cable glands, XCL-VEA-TUB tubing interface and XCL-COVER sensor cover with gasket. Each unit terminates its field cabling in pluggable rising clamp connections.
Specifications
| Ordering code description | 5 x VESDA Sensepoint XCL H 1000ppm 4-20mA Relay for VEA |
|---|---|
| Gas detected | Hydrogen (H₂): 1000ppm |
| Supply voltage | 24 VDC nominal; 11 to 32V DC (Analog 4-20 mA); 9 to 32V DC (Modbus); 24V AC 50/60Hz Nominal (20 to 27 VAC) |
| Maximum power consumption 24v dc | 1.2 W (Analog 4-20mA) (toxic), 1.7W (flammable and CO₂); 0.7 W (Modbus) (toxic), 1.2W (flammable and CO₂); Relay Version: additional 0.6W total |
| Maximum inrush current 24v dc | 850 mA |
| Output | Analog Output: 0 to 22 mA; Digital Output: Modbus RTU; Relay Output: 2 relays (24 V DC / 250 V AC, 5 A) |
| Dimensions wxhxd | 113 x 113 x 59 mm (4.4 x 4.4 x 2.3 in) |
| Weight | 500 g (1.1 lb) |
|---|---|
| Ingress protection | IP65, Type 4 (NEMA 250) |
| Casing material | Polycarbonate (charcoal colour) |
| Operating temperature | −20 to +50 °C (−4 to +122 °F) |
| Storage temperature | 0 to +30 °C (+32 to +86 °F) |
| Humidity | 0 to 99% (non-condensing) |
| Atmospheric pressure | 95 to 110 kPa |
Specifications per manufacturer documentation, subject to change. E&OE.
Spares & replacement parts
- XCL-XRL-SC-H2XCL/XRL Replacement Sensor Hydrogen (H2)Replacement H2 sensor cartridge for the XCL H2 detector.£346.15ex VAT£415.38 inc VATIn stock