Gas Detection XCL

VESDA Sensepoint XCL XCL-VEA-CO2VV-RA CO2 Detector 5% v/v

Ordering code description
VESDA Sensepoint XCL CO2 5% v/v 4-20mA Relay for VEA
Gas detected
Carbon Dioxide (CO2): 5.0% v/v (adjustable 1.0 – 5.0% v/v)
Supply voltage
24 VDC nominal; 11 to 32V DC (Analog 4-20 mA); 9 to 32V DC (Modbus); 24V AC 50/60Hz Nominal (20 to 27 VAC)
Maximum power consumption 24vdc
1.2 W (Analog 4-20mA) (toxic), 1.7W (flammable and CO2); 0.7 W (Modbus) (toxic), 1.2W (flammable and CO2); Relay Version: additional 0.6W total
Maximum inrush current 24vdc
850 mA
Ingress protection
IP65, Type 4 (NEMA 250)
Operating temperature
−20 to +50 °C (−4 to +122 °F)

Overview

What it is and how it fits the system.

The XCL-VEA-CO2VV-RA is a VESDA Sensepoint XCL aspirated carbon dioxide (CO2) gas detector that inserts in-line into a VESDA-E VEA micro bore tube network, set to 5.0% v/v and adjustable from 1.0 to 5.0% v/v. It provides 0 to 22 mA analogue output plus relays, runs on 24V DC nominal and is rated IP65 in a 113 x 113 x 59 mm polycarbonate housing.

Technical overview

XCL-VEA-CO2VV-RA places carbon dioxide monitoring directly within a VESDA-E VEA micro bore tube network: an Xtralis VESDA Sensepoint XCL aspirated gas detector in the 4-20 mA relay version. Set to 5.0% v/v and adjustable down to 1.0% v/v, the detector inserts in-line to the tube network, connecting to the 6 mm (1/4 in) OD micro bore tube through flexible tubes.

Signals leave the unit three ways — an analogue output spanning 0 to 22 mA, Modbus RTU digital communications and a pair of relays — allowing integration with fire alarm control panels, PLCs, HVAC and building management systems. VSC and VSM4 provide remote access to detectors over Modbus, a compatible smart device running iOS 10 or Android 4.3 and above connects from up to 10 m away over Bluetooth 4.0 (mobile device dependent), and integral LEDs show alarm status at the detector.

The XCL-SC-CO2VV replacement sensor cartridge renews the CO2 sensing element, while the accessory list covers the XCL-VEA-CAL calibration/flow cap, XCL-VEA-TUB tubing interface, XCL-FILTER replacement filters, XCL-M20-CG cable glands and XCL-COVER sensor cover. Electrical safety conforms to EN/UL/IEC61010-1 and is certified to CSA-C22.2 No. 61010-1-12, EMC approval is CE - EMC; EN 50270, radio approvals are RED, FCC, BT SIG, and terminal connections and the tube insertion procedure are detailed in the installation manual.

Specifications

Full technical data for this part.

Ordering code descriptionVESDA Sensepoint XCL CO2 5% v/v 4-20mA Relay for VEA
Gas detectedCarbon Dioxide (CO2): 5.0% v/v (adjustable 1.0 – 5.0% v/v)
Supply voltage24 VDC nominal; 11 to 32V DC (Analog 4-20 mA); 9 to 32V DC (Modbus); 24V AC 50/60Hz Nominal (20 to 27 VAC)
Maximum power consumption 24vdc1.2 W (Analog 4-20mA) (toxic), 1.7W (flammable and CO2); 0.7 W (Modbus) (toxic), 1.2W (flammable and CO2); Relay Version: additional 0.6W total
Maximum inrush current 24vdc850 mA
OutputAnalog Output: 0 to 22 mA; Digital Output: Modbus RTU; Relay Output: 2 relays (24 V DC / 250 V AC, 5 A)
Dimensions wxhxd113 x 113 x 59 mm (4.4 x 4.4 x 2.3 in)
Weight500 g (1.1 lb)
Ingress protectionIP65, Type 4 (NEMA 250)
Casing materialPolycarbonate (charcoal colour)
Operating temperature−20 to +50 °C (−4 to +122 °F)
Storage temperature0 to +30 °C (+32 to +86 °F)
Humidity0 to 99% (non-condensing)
Atmospheric pressure95 to 110 kPa

Specifications sourced from manufacturer documentation.

Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know