VESDA Sensepoint XCL XCL-VEA-CO2PP-RA CO2 Detector 5000ppm

Ordering code description
VESDA Sensepoint XCL CO 5000ppm 4-20mA Relay 2 for VEA
Gas measured
Carbon Dioxide (CO 2 ): 5000ppm (adjustable 1000 – …)
Supply voltage
24 VDC nominal; 11 to 32V DC (Analog 4-20 mA); 9 to 32V DC (Modbus); 24V AC 50/60Hz Nominal (20 to 27 VAC)
Maximum power consumption 24v dc
1.2 W (Analog 4-20mA) (toxic), 1.7W (flammable and CO 2); 0.7 W (Modbus) (toxic), 1.2W (flammable and CO 2); Relay Version: additional 0.6W total
Maximum inrush current 24v dc
850 mA
Ingress protection
IP65, Type 4 (NEMA 250)
Operating temperature
−20 to +50 °C (−4 to +122 °F)

Overview

What it is and how it fits the system.

The XCL-VEA-CO2PP-RA is a VESDA Sensepoint XCL aspirated carbon dioxide (CO2) gas detector that inserts in-line into a VESDA-E VEA micro bore tube network, with a 5000ppm range. It provides 0 to 22 mA analogue output plus two relays, runs on 24V DC nominal and is rated IP65 (Type 4 / NEMA 250) in a 113 x 113 x 59 mm polycarbonate housing.

Technical overview

XCL-VEA-CO2PP-RA measures carbon dioxide at parts-per-million level on VESDA-E VEA microbore tube networks, an Xtralis aspirated gas detector in the VESDA Sensepoint XCL family with a 5000 ppm range, 4-20 mA analogue signalling and relay outputs. That range is adjustable from 1000 ppm, and the sensing element has a dedicated spare in the XCL-SC-CO2PP replacement sensor at the matching 5000 ppm rating.

Tube work at the detector is closely specified: flexible tube sections cut to 50 mm make the connections, VEA tubes seat at least 15 mm into those sections, and tube clips hold the joints to the 6 mm outside-diameter network. Detectors can be brought into VESDA-E VEA installations new or existing.

On the building side, the analogue output and two relays connect fire alarm control panels, PLCs, HVAC and building management systems, with VSC and VSM4 integration also available, and Bluetooth Low Energy connects a compatible smart device up to 10 m away (mobile device dependent). Approvals span conformity to EN/UL/IEC61010-1, certification to CSA-C22.2 No. 61010-1-12, EN 50270 for EMC and RED, FCC, BT SIG for radio; the XCL-VEA-CAL Calibration/Flow Cap for VEA pairs with the detector, and terminal wiring is detailed in the installation manual.

Specifications

Full technical data for this part.

Ordering code descriptionVESDA Sensepoint XCL CO 5000ppm 4-20mA Relay 2 for VEA
Gas measuredCarbon Dioxide (CO 2 ): 5000ppm (adjustable 1000 – …)
Supply voltage24 VDC nominal; 11 to 32V DC (Analog 4-20 mA); 9 to 32V DC (Modbus); 24V AC 50/60Hz Nominal (20 to 27 VAC)
Maximum power consumption 24v dc1.2 W (Analog 4-20mA) (toxic), 1.7W (flammable and CO 2); 0.7 W (Modbus) (toxic), 1.2W (flammable and CO 2); Relay Version: additional 0.6W total
Maximum inrush current 24v dc850 mA
OutputAnalog Output: 0 to 22 mA; Digital Output: Modbus RTU; Relay Output: 2 relays (24 V DC / 250 V AC, 5 A)
Dimensions wxhxd113 x 113 x 59 mm (4.4 x 4.4 x 2.3 in)
Weight500 g (1.1 lb)
Ingress protectionIP65, Type 4 (NEMA 250)
Casing materialPolycarbonate (charcoal colour)
Operating temperature−20 to +50 °C (−4 to +122 °F)
Storage temperature0 to +30 °C (+32 to +86 °F)
Humidity0 to 99% (non-condensing)
Atmospheric pressure95 to 110 kPa

Specifications sourced from manufacturer documentation.

Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know

Spares & replacement parts

Replacement parts for units already in service.

XCL-SC-CO2PP

VESDA RPL SENS CO2 5000PPM SP XCL

Replacement CO2 5000ppm sensor cartridge for the XCL CO2 5000ppm detector.

£396.75
ex VAT
£476.10 inc VAT
Sold separately