Gas Detection XCL
VESDA Sensepoint XCL XCL-VEA-CO-RM CO Modbus Detector
- Gas detected
- Carbon Monoxide (CO): 300ppm (adjustable 50 – 1000ppm)
- Output type
- Modbus Relay for VEA
- Supply voltage
- 24 VDC nominal; 9 to 32V DC (Modbus); 24V AC 50/60Hz Nominal (20 to 27 VAC)
- Maximum power consumption (24v dc)
- 0.7 W (Modbus) (toxic); Relay Version: additional 0.6W total
- Maximum inrush current (24v dc)
- 850 mA
- Ingress protection
- IP65, Type 4 (NEMA 250)
- Operating temperature
- −20 to +50 °C (−4 to +122 °F)
Overview
What it is and how it fits the system.
The XCL-VEA-CO-RM is a VESDA Sensepoint XCL aspirated carbon monoxide (CO) gas detector that inserts in-line into a VESDA-E VEA micro bore tube network, set to 300ppm and adjustable from 50 to 1000ppm. It provides Modbus RTU output plus relays, draws 0.7 W on 24V DC, and is housed in an IP65-rated 113 x 113 x 59 mm polycarbonate enclosure.
Technical overview
XCL-VEA-CO-RM is an Xtralis VESDA Sensepoint XCL aspirated carbon monoxide detector for the VESDA-E VEA microbore tube network, built in the Modbus-and-relay output configuration. Reporting over RS 485 Modbus brings VSC and VSM4 integration for remote access to detectors, alongside connections into fire alarm control panels, PLCs, HVAC and building management systems.
Set-up uses a compatible smart device running iOS 10 or Android 4.3 or above, connecting over Bluetooth at up to 10 m depending on the mobile device, and integral LEDs give local alarm indication. The detector draws from the VEA's 6 mm micro bore tubing through flexible tube couplings, sitting in-line within the network.
Sensor spares use the XCL-XRL-SC-CO cartridge, a part shared with XRL detectors. The XCL-VEA-CAL calibration and flow cap, XCL-FILTER filter packs, XCL-M20-CG cable glands and XCL-COVER sensor cover are the listed accessories, with XCL-VEA-TUB as the tubing interface for VEA. Electrical safety conformity is to EN/UL/IEC61010-1 with certification to CSA-C22.2 No. 61010-1-12, and physical wiring detail is held in the installation manual.
Specifications
Full technical data for this part.
| Gas detected | Carbon Monoxide (CO): 300ppm (adjustable 50 – 1000ppm) |
|---|---|
| Output type | Modbus Relay for VEA |
| Supply voltage | 24 VDC nominal; 9 to 32V DC (Modbus); 24V AC 50/60Hz Nominal (20 to 27 VAC) |
| Maximum power consumption (24v dc) | 0.7 W (Modbus) (toxic); Relay Version: additional 0.6W total |
| Maximum inrush current (24v dc) | 850 mA |
| Output | Analog Output: 0 to 22 mA; Digital Output: Modbus RTU; Relay Output: 2 relays (24 V DC / 250 V AC, 5 A) |
| Dimensions (wxhxd) | 113 x 113 x 59 mm (4.4 x 4.4 x 2.3 in) |
| Weight | 500 g (1.1 lb) |
| Ingress protection | IP65, Type 4 (NEMA 250) |
| Casing material | Polycarbonate (charcoal colour) |
| Operating temperature | −20 to +50 °C (−4 to +122 °F) |
| Storage temperature | 0 to +30 °C (+32 to +86 °F) |
| Humidity | 0 to 99% (non-condensing) |
| Atmospheric pressure | 95 to 110 kPa |
Specifications sourced from manufacturer documentation.