VESDA XCL Oxygen (O2) 0 to 25 %v/V, (Modbus & Relays)

Part no.XCL-LB-O2-RM
BrandVESDA
RangeGas Detection XCL
Esser XCL-LB-O2-RM black rectangular ammonia gas detector with red test button and mounting bracket. — main product photo

Image for illustration; item supplied may differ

Description

The XCL-LB-O2-RM is a VESDA Sensepoint XCL Large Bore oxygen (O2) gas detector with a 25% V/V measuring range. Combining Modbus digital output with an integral relay, it reports oxygen levels over a networked bus while driving local alarm and control outputs.

XCL-LB-O2-RM measures oxygen over a 25% V/V range as the Modbus-plus-relay build of the Xtralis VESDA Sensepoint XCL Large Bore gas detector. The electrochemical-cell-type sensor reports over Modbus RTU at a default 9600 bps while the on-board relay, rated 5 A, 250 V AC, 24 V DC, drives local alarm and control outputs; the Sensepoint App handles configuration, including recovery from EEPROM or flash faults.

Read the full technical description

Supply options are nominal 24 V DC or 24 V AC, 50/60 Hz, with the Modbus version accepting 9 to 32 V DC and inrush current below 850 mA; consumption is 0.3 W in the normal state and 0.7 W in alarm, plus 0.6 W for the relay output stage. The IP65 housing measures 113 mm by 113 mm by 59 mm and weighs 500 g, and the detector operates from −20 to 50 °C, 0 to 99% non-condensing humidity and 90 to 110 kPa. EMC compliance is to EN 50270:2015, with electrical safety to UL 61010-1, CSA C22.2 No. 61010-1, IEC/EN 61010-1.

The oxygen cell can be renewed in service with the XCL-SC-O2 replacement sensor, and family accessories cover XCL-M20-CG cable glands (pack of 10), the XCL-LB-CAP flow cap and XCL-LB-ELB 60° pipe elbows (pack of 4). Physical wiring, including the mA-output loopback resistor connection, is set out in the installation manual.

Specifications

WarrantyXtralis warrants the VESDA Sensepoint XCL gas detector against defective parts and workmanship.
Warranty exclusionsThis warranty does not cover consumable, batteries, fuses, normal wear and tear, or damage caused by accident, abuse, improper installation, unauthorized use, modification or repair, ambient environment, poisons, contaminants or abnormal operating conditions.
Length113 mm (4.4 in)
Width113 mm (4.4 in)
Height59 mm (2.3 in)
Weight500 g (1.1 lb)
Nominal DC input voltage24 V DC
Nominal AC input voltage24 V AC, 50/60 Hz
DC operating voltage range (Modbus version)9 to 32 V DC
Inrush currentLess than 850 mA
Digital outputModbus RTU
Modbus baud rate (default)9600 bps
Relay output rating5 A, 250 V AC, 24 V DC
Sensor typeElectrochemical-cell-type
Power consumption (digital output version)0.3 W normal state, 0.7 W during alarm
Additional power consumption (relay output version)0.6 W
Operating temperature−20 to 50 °C (−4 to 122 °F)
Storage temperature0 to 30 °C (32 to 86 °F)
Humidity0 to 99% (non-condensing)
Atmospheric pressure90 to 110 kPa
IP ratingIP65
EMC standardEN 50270:2015
Electrical safetyUL 61010-1, CSA C22.2 No. 61010-1, IEC/EN 61010-1

Specifications per manufacturer documentation, subject to change. E&OE.