Skip to content

Trade prices shown ex VAT. Order by 3pm for same-day dispatch on stocked lines, UK mainland. Free UK delivery on orders over £250 ex VAT.

Part Number or the Week S3EP-V-VAD-HPR-R

System Sensor Red Flash, Pure White Body, Clear Lens c/w Isolator. Loop-powered EN54-23 Open Category Detector Base Sounder Strobe in pure white. Requires a B501AP base for fast and simple installation for System Sensor detectors and a choice of sound output levels and tones selectable from the device or panel

Part no.DSS-PC-I00
BrandSystem Sensor
RangeAddressable Audio Visual Devices
Sub-rangeBase Sounder VAD
DSS-PC-I00 Isolated Base Sounder Strobe — white circular unit, clear lens, top wiring terminals

Image for illustration; item supplied may differ

At a glance

  • EN54-23 Open CategoryDSS-PC-I00 carries the EN54-23 Open Category classification.
  • Loop Powered Base DevicePower is taken from the loop.
  • Isolated VersionThis is the isolated version of the base sounder strobe.
  • Pure White Clear LensThe body is pure white and the lens is clear.
  • Red FlashThe strobe gives a red flash.
  • Selectable Levels And TonesA choice of sound output levels and tones is selectable from the device or panel.
  • Fits B501AP BaseThe device fits a B501AP base, the base used for System Sensor detectors.

Description

This is the isolated version of the pure white detector base sounder strobe, classified under EN54-23 as Open Category. Power is taken from the loop.

The lens is clear and the flash is red. Sound output level and tone are both selectable, either at the device or from the panel. Mounting is onto a B501AP base, the base used for System Sensor detectors.

Read the full technical description

DSS-PC-I00 is a detector base sounder strobe that carries the EN54-23 Open Category classification and is the isolated version of the device. It takes its power from the loop, and the body is pure white with a clear lens and a red flash. A choice of sound output levels and tones is selectable from the device or the panel. The unit fits a B501AP base, the base used for System Sensor detectors.

Specifications

Operating voltage24 VDC nominal (18-32 VDC) - Regulated.
Power consumption1.8 watts (nominal); 2.4 watts (Alarm); 12 Watts (max) = 0.50A @ 24V with heater ON 100% duty cycle.
Inrush currentInrush Current is 0.75A for a maximum duration of less than 5ms.
OutputsFault, Alarm and Auxiliary SPDT relays Max. 32 Vdc/ac, max. 2 A, min 10 mA at 12 V resistive load. 4-20 mA source, sink or isolated current output. Uncertainty is 1% of reading. FP2 over RS-485 and USB (USB is accessible through Detector Module electronic device only). Modbus over RS-485.
4-20 ma output4-20 mA Source, sink or isolated current output.
CommunicationsFP2 over RS-485 and USB; Modbus over RS-485; HART® 7 communication registered with FieldComm Group, EDD/DTM files available.
WeightAluminum 3 lbs. 11 oz. (1.7 kg); Stainless Steel 7 lbs. 7 oz. (3.4 kg)
Housing materialLow Copper (less than 0.25%) marine grade Painted casted Aluminum of ASTM A356.0 grade. Polished cast Stainless Steel of ASTM CF8M grade.
EnclosureDiameter: 125 mm (4.92 in) x 115 mm (4.52 in) deep; Two M25 X 1.5P or two ¾'' NPT conduit entries.
Window sizeWindow size diameter: 79 mm (3.11 in)
Operating temperature north americaOperating Temperature (North America): -50°C to +75°C
Operating temperature atex iecexOperating Temperature (ATEX/IECEx): -55°C to +75°C
Storage temperature north americaStorage Temperature (North America): -50°C to +85°C
Storage temperature atex iecexStorage Temperature (ATEX/IECEx): -55°C to +85°C

Specifications per manufacturer documentation, subject to change. E&OE.