Morley-IAS MA-2000-01 Main conrtol board including display LCD - Region 1
| Part no. | 5000.00.010 |
|---|---|
| Brand | Morley-IAS |
| Range | Morley Max |
| Sub-range | Fire Panel Spares |
Image for illustration; item supplied may differ
At a glance
- Main Board With LCD5000.00.010 is the Main board + LCD, Version 01.
- MA-2000 Panel SpareThe board is kept as a spare for the MA-2000 control panel of the fire alarm system.
- Qualified Electricians OnlyReplacement of the board and recommissioning may only be carried out by qualified electricians.
- Power Removed FirstAll power is removed from the panel before any installation work is carried out.
- One Minute WaitA wait of 1 minute confirms the panel is no longer energised.
- Panel Door AccessThe 2 screws are removed so the panel door can be opened.
Description
Main board + LCD, Version 01 is the main board together with its LCD, and 5000.00.010 is the number under which that board is kept as a spare for an MA-2000.
Preparation ahead of the swap disconnects the control panel completely from the mains voltage and switches off the fuse for main power. The replacement of spare parts and recommissioning of the devices may only be carried out by qualified electricians. Danger of electrical shock: all power is removed from the panel before carrying out any installation work. The factory-installed fuses are never repaired, bypassed or replaced with a type other than the one specified.
5000.00.010 is the Main board + LCD, Version 01, the main board with its LCD held as a spare for the MA-2000 control panel of the fire alarm system. It carries the Version 01 designation, and 5000.00.010 is the number tied to that version of the board.
Only qualified electricians may replace the board and recommission the equipment afterwards. Danger of electrical shock means all power is removed from the panel before any installation work starts, and a wait of 1 minute confirms it is de-energised. The battery cable is then unplugged at the batteries and again at the board, the main power supply connector is unplugged, and the battery probe is taken off the board. The 2 screws are removed so the panel door can be opened.
Read the full technical description
All voltage and signal lines are secured with suitable fastening material, such as plastic cable fasteners, so that they cannot come loose or be moved, and the power supply line is kept where it cannot touch the signal lines carrying SELV. The necessary precautions against electrostatic discharge must be taken while any electronic assembly is handled. Once recommissioning is complete, a complete function test of the system is performed.
5000.00.010 is the Main board + LCD, Version 01, the main board with its LCD held as a spare for the MA-2000 control panel of the fire alarm system. It carries the Version 01 designation, and 5000.00.010 is the number tied to that version of the board.
Only qualified electricians may replace the board and recommission the equipment afterwards. Danger of electrical shock means all power is removed from the panel before any installation work starts, and a wait of 1 minute confirms it is de-energised. The battery cable is then unplugged at the batteries and again at the board, the main power supply connector is unplugged, and the battery probe is taken off the board. The 2 screws are removed so the panel door can be opened.
While electronic assemblies are handled, the necessary precautions against electrostatic discharge must be taken. Factory-installed fuses are never repaired, bypassed or replaced by a type other than the one specified.
Specifications
| Description | Main board + LCD, Version 01 |
|---|---|
| Spare part category | SPARE PARTS |
Specifications per manufacturer documentation, subject to change. E&OE.
Optional accessories
- MA-2000-01Morley-IAS Max two loop (networkable) For System Sensor & Apollo protocolspare main control board used in the MA-2000 panel£1,017.20ex VAT£1,220.64 inc VATIn stock