Morley-IAS Low Profile Non-Addressable Optical Smoke Detector Compatible with the D2E Duct Detector.
| Part no. | 2351E A |
|---|---|
| Brand | Morley-IAS |
| Range | Morley Conventional Duct |
| Sub-range | Detector |

Image for illustration; item supplied may differ
At a glance
- Low Profile Optical Detector2351E A is a low profile non-addressable optical smoke detector.
- Photoelectric ASIC SensingAn Application Specific Integrated Circuit (ASIC) combined with the optical chamber provides efficient and accurate detection of fires with a high level of resilience to non-fire environmental influences.
- Wide Supply RangeOperating voltage is 8 to 30VDC, nominal 12/24VDC.
- Low Standby CurrentTypical standby current is 50µA @ 24VDC with no LED blink.
- Panel Limited Alarm CurrentMaximum alarm current with the LED on is 80mA @ 24VDC, limited by the panel.
- Compact HousingThe detector is 102mm in diameter, 38mm high and weighs 105g.
- Wide Environmental RangeOperation covers -30°C to 70°C at 5 to 95% relative humidity, non condensing.
Description
Photoelectric smoke sensing is what 2351E A brings to installations built around non-addressable devices. Its optical chamber is paired with an Application Specific Integrated Circuit (ASIC), a combination that keeps detection of fires both efficient and accurate while resisting non-fire environmental influences.
Supply can sit anywhere between 8 to 30VDC, nominally 12/24VDC. Typical quiescent consumption is 50µA @ 24VDC where the LED does not blink, and the alarm figure peaks at 80mA @ 24VDC with the LED on, a maximum the panel itself limits.
2351E A is a low profile non-addressable optical smoke detector that senses fire photoelectrically. An Application Specific Integrated Circuit (ASIC) works alongside the optical chamber to give efficient and accurate detection of fires, together with a high level of resilience to non-fire environmental influences.
The head accepts anything from 8 to 30VDC, with a nominal figure of 12/24VDC. Typical standby draw is 50µA @ 24VDC with the LED not blinking, while the maximum alarm current with the LED on is 80mA @ 24VDC, limited by the panel.
Read the full technical description
Mechanically the housing spans 102mm across and stands 38mm high at a mass of 105g. Ambient operation is rated across -30°C to 70°C and 5 to 95% relative humidity, non condensing.
2351E A is a low profile non-addressable optical smoke detector that senses fire photoelectrically. An Application Specific Integrated Circuit (ASIC) works alongside the optical chamber to give efficient and accurate detection of fires, together with a high level of resilience to non-fire environmental influences.
The head accepts anything from 8 to 30VDC, with a nominal figure of 12/24VDC. Typical standby draw is 50µA @ 24VDC with the LED not blinking, while the maximum alarm current with the LED on is 80mA @ 24VDC, limited by the panel.
The low profile body is 102mm in diameter and 38mm high, and the detector weighs 105g. Its working temperature range runs from -30°C to 70°C, and it will tolerate 5 to 95% relative humidity, non condensing.
Specifications
| Order part number | 2351E |
|---|---|
| Commercial part number | 2351 E A |
| Description | OPTICAL CONVENTIONAL SMOKE DETECTOR |
Specifications per manufacturer documentation, subject to change. E&OE.