Morley 22051TLEI-26 Smoke/Thermal/IR + Isolator

integral_isolator
with isolator
Weight
102g (inc base)
Height
63mm installed in B501AP base
Diameter
102mm installed in B501AP base
max_wire_gauge_for_terminals
2.5mm 2
operating_voltage_range
15 to 32Vdc
maximum_standby_current
200 µ A at 24Vdc (no communications) 300 µ A at 24Vdc ( LED blink enabled, once every 5s)

Overview

What it is and how it fits the system.

The Morley 22051TLEI-26 is a multi-criteria detector combining smoke, thermal and infrared sensing with a built-in isolator in a white housing. The integral isolator preserves loop continuity if a wiring fault occurs, while the three sensing channels widen fire detection coverage on addressable systems.

Technical overview

The 22051TLEI-26 is a white-housed Morley multi-criteria detector that reads three fire signatures at once, drawing on photoelectric smoke, heat, and infrared channels with an isolator built in. Its integral isolator holds the loop's continuity should a wiring fault arise, and together the three channels broaden the fire-detection reach across an addressable system.

Its integral isolator function maintains circuit integrity if a fault occurs, allowing continued operation of other devices on the loop. The three sensing channels—photoelectric, thermal, and infrared—provide enhanced discrimination and responsiveness across varied fire signatures compared to single-sensor alternatives.

Compatibility is specified for installation in the B501AP base, as noted in the supported configuration. For detailed physical connection procedures, users must consult the official installation manual referenced in the wiring guidance.

Specifications

Full technical data for this part.

integral_isolatorwith isolator
Weight102g (inc base)
Height63mm installed in B501AP base
Diameter102mm installed in B501AP base
max_wire_gauge_for_terminals2.5mm 2
ColourWhite
Material / ConstructionPC/ABS
operating_voltage_range15 to 32Vdc
maximum_standby_current200 µ A at 24Vdc (no communications) 300 µ A at 24Vdc ( LED blink enabled, once every 5s)
led_current3.5mA at 24Vdc
temperature_range-30°C to +70°C
Relative Humidity10 to 93% relative humidity (non-condensing)
addressable_systemsSystem Sensor Protocol Analogue Addressable Field Devices
sensitivity_alarm_level_1Low false alarm resistance, high photoelectric only sensitivity. 1%/ft smoke
sensitivity_alarm_level_2Medium false alarm resistance, medium photoelectric only sensitivity. 2%/ft smoke
sensitivity_alarm_level_3Standard false alarm resistance, low photoelectric only sensitivity. 3%/ft smoke
sensitivity_alarm_level_4High false alarm resistance, low photoelectric only sensitivity. 3%/ft smoke
sensitivity_alarm_level_5Very high false alarm resistance, low photoelectric only sensitivity. 3%/ft smoke
sensitivity_alarm_level_6Heat sensor - Class A1R

Specifications sourced from manufacturer documentation.

Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know