Morley-IAS HRZ-4e, 4 Zone Non-Addressable Fire Alarm Control Panel. 4 detection zones, 2 sounder outputs, surface mounting, fire and fault relays. 318 x 356 x 92mm (H x W x D)

Part no.002-492-242
BrandMorley-IAS
RangeConventional Horizon Panels
Sub-rangeFire Panel
Morley-IAS 002-492-242 Horizon HRZ4E 4-Zone Fire Panel — white case, blue front with horizon logo, log fields, keyhole.

Image for illustration; item supplied may differ

Description

The Morley-IAS Horizon HRZ4E is a 4-zone conventional fire alarm control panel supplied complete with the 020-713 fire & fault relay. It supports 2, 4 or 8 detection circuits drawing 2mA each (typically more than 20 detectors per circuit), with two monitored sounder outputs at 0.5A per circuit and a 0.5A auxiliary output at 18.5 to 28.5Vdc. Powered from 230Vac with an internal supply delivering up to 1.8A, it handles a maximum 1A alarm load for mid-sized conventional systems.

002-492-242 identifies the Morley-IAS Horizon HRZ4E, a four-zone conventional fire alarm control panel from the Horizon range, designed to comply with EN54 part 2 and part 4. Within a platform built in 2, 4 or 8 detection circuit versions, this order code is the four-zone point: each detection circuit draws 2 mA and typically carries more than 20 detectors.

Read the full technical description

002-492-242 identifies the Morley-IAS Horizon HRZ4E, a four-zone conventional fire alarm control panel from the Horizon range, designed to comply with EN54 part 2 and part 4. Within a platform built in 2, 4 or 8 detection circuit versions, this order code is the four-zone point: each detection circuit draws 2 mA and typically carries more than 20 detectors.

Alarm distribution runs through two monitored sounder outputs at 0.5 A per circuit, backed by an auxiliary DC output and, via the optional relay card, a fire relay with changeover contacts. Approved detector choices span Apollo Series 60 (wide voltage), Series 65 and Orbis alongside System Sensor ECO1000 and Series 300. For commissioning and false alarm management the panel offers a walk test facility, coincidence detection and programmable delays that allow alarm verification, with multilingual text inserts and 22 configurable inputs assignable to class change, alert, evacuate and reset functions.

Option hardware extends the base panel: the 020-713 Horizon relay kit adds fire and fault relays, the 020-772 four-way sounder output card and 020-747 eight-way input/output card grow the output count, and end-of-line arrangements are covered by the 020-417 active end-of-line kit or the 020-743 capacitor kit for detectors that do not suit capacitive EOL monitoring.

Specifications

Panel type4 Zone Conventional Fire Alarm Control Panel
Detection circuits2, 4 or 8 detection circuits
Detection circuit current2 mA per circuit (typically >20 detectors)
Operating voltage230 Vac 50/60 Hz (±15%)
Internal power supply output voltage+18.5 to +28.5 Vdc
Internal power supply output current1.8 Amps maximum
Maximum alarm load1 Amp
Sounder outputs2 monitored outputs, 0.5 Amps per circuit
Auxiliary output+18.5 to +28.5 Vdc, 0.5 Amp. (max)
Optional relay card1 x Fire relay (changeover contacts rating 30Vdc, 1 Amp)
Digital inputs22 configurable inputs (Class Change, Alert, Evacuate, Reset)
Digital input triggerExtended closing contact
Standby batteries minimum capacityMinimum capacity 2 x 12 V 2.8Ah

Specifications per manufacturer documentation, subject to change. E&OE.

Documents

DocumentTypeSizeDownload
Datasheet (002-492-222, 002-492-242, 002-492-282)Datasheet174 KBDownload PDF
Datasheet (002-492-222, 002-492-242, 002-492-282, 020-417, 020-713 +4 more)Datasheet2.1 MBDownload PDF

Optional accessories