ex-VAT pricing shown

Now open for trade ordersGent, Morley-IAS & Xtralis stock added weekly — open to the trade.

Conventional Horizon Panels

Morley HRZ2E 2 Zone Conventional Fire Panel

Panel type
2, 4 & 8 Zone Conventional Fire Alarm Control Panels
Zones
2 Zone (HRZ2E)
Operating voltage
230 Vac 50/60 Hz (±15%)
Internal power supply output voltage
+18.5 to +28.5 Vdc
Output current
1.8 Amps maximum
Maximum alarm load
1 Amp
Standby battery minimum capacity
Minimum capacity 2 x 12 V 2.8Ah

Overview

What it is and how it fits the system.

The Morley-IAS Horizon HRZ2E is a 2-zone conventional fire alarm control panel from the Horizon HRZ Series, supplied complete with the 020-713 fire & fault relay. Running on a 230Vac 50/60Hz supply, it delivers up to 1.8A from an 18.5 to 28.5Vdc internal power supply and supports a maximum 1A alarm load. Two monitored sounder outputs rated 0.5A per circuit and sealed lead-acid standby batteries from 2.8Ah to 7Ah make it a dependable choice for compact two-zone installations.

Technical overview

The Conventional Horizon HRZ2E is a compact two-zone conventional fire alarm control panel (002-492-222) built for smaller installations. It runs from a 230 Vac 50/60 Hz mains supply with a ±15% tolerance, and its internal power supply delivers a regulated DC output of between +18.5 and +28.5 Vdc, rated to 1.8 Amps. Alarm loading is capped at 1 Amp, and two monitored sounder circuits are provided, each rated at 0.5 Amps.

Standby power comes from sealed lead-acid batteries, accommodating pairs of 12 V cells from 2.8Ah up to 7Ah so run-time can be matched to the site. An auxiliary output offers the same +18.5 to +28.5 Vdc rail at up to 0.5 Amp, while 22 configurable digital inputs cover functions including Class Change, Alert, Evacuate and Reset. Detection wiring can be arranged as 2, 4 or 8 circuits, each drawing around 2 mA and typically carrying more than 20 detectors, giving flexibility as the layout grows.

Specifications

Full technical data for this part.

Panel type2, 4 & 8 Zone Conventional Fire Alarm Control Panels
Zones2 Zone (HRZ2E)
Operating voltage230 Vac 50/60 Hz (±15%)
Internal power supply output voltage+18.5 to +28.5 Vdc
Output current1.8 Amps maximum
Maximum alarm load1 Amp
Standby battery minimum capacityMinimum capacity 2 x 12 V 2.8Ah
Standby battery maximum capacityMaximum capacity 2 x 12 V 7 Ah
Standby battery typeSealed lead acid
Sounder outputs2 monitored outputs, 0.5 Amps per circuit
Auxiliary output+18.5 to +28.5 Vdc, 0.5 Amp. (max)
Detection circuits2, 4 or 8 detection circuits
Detection circuit current2 mA per circuit (typically >20 detectors)
Digital inputs22 configurable inputs (Class Change, Alert, Evacuate, Reset)

Specifications sourced from manufacturer documentation.

Specifications per manufacturer documentation, subject to change — E&OE. Spotted an inaccuracy? Let us know

Optional accessories

Optional additions — this product works without them.

020-417

Active end of line monitor module

compatible / works with: Active end of line monitor module

£39.47
ex VAT
£47.36 inc VAT
Sold separately
020-743

Capacitor kit for detectors not compatible with capacitive EOL monitoring. Includes 8 x 10µƒ capacitors. Active EOL's required - See part number 020-417

compatible / works with: Capacitor kit for detectors not compatible with capacitive E

£31.63
ex VAT
£37.96 inc VAT
Sold separately
020-747

8-way input / output card. Provides up to 8 configurable relay outputs or up to 4 command inputs and 4 outputs

compatible / works with: 8-way input / output card. Provides up to 8 configurable rel

£143.75
ex VAT
£172.50 inc VAT
Sold separately
020-713

Fire & fault relay module for NFS2-8

Optional fire & fault relay kit for the Horizon panel.

£46.05
ex VAT
£55.26 inc VAT
Sold separately

Datasheets & documents